MULTIREG LCD2 Installation Manual Download Page 2

CONNECTIONS:

Torque: 2Nm
Terminal 1: S (connected to L for setback temperature)
Terminal 2: L
Terminal 3: N
Terminal 4+5: NTC - Floor sensor
Terminal 6+7: Max. load 3600W (LOAD)

STARTUP/CLOCK SET 

After the thermostat is connected to 230V and you press the 
on/off button, the thermostat will switch on at 20°C. The 
time display will flash 00:00. The thermostat is now in room 
temperature sensor mode with set temperature and the symbol 

is shown in the display.

Before programming your thermostat, you must set the clock.

Press the OK button for 5 seconds.  When the clock symbol      
flahes, press OK once.
Choose whether or not you want to display the time (on/off ). 
(Set temperature does not require the clock to be set.) 
Confirm with the OK button.  
If you choose OFF, the thermostat is ready to be used in set 
temperature mode. For use with other modes, choose ON.
Choose the day of the week. 1=Monday, 2=Tuesday etc. Confirm 
with OK.
Set the hours and minutes. Confirm with OK. The clock symbol      
flashes. Continue to the next paragraph: Choosing a program.

When the 

symbol is shown in the display, it indicates that 

the heat is on.

CHOOSING A PROGRAM

a) Set temperature

When the symbol 

is shown in the display, the thermostat is 

programmed to the set temperature option. To switch between 
set temperature and weekly program press the OK button and 
the left selection button simultaneously for 5 seconds.

b) Weekly program - setback temperature

Press the OK button and the left selection button 
simultaneously for 5 seconds.
Weekly schedule is shown with 

symbol in the display. 

Fig.2

1

2

3

4

5

6

7

OK-button  

(changing functions) 

Fig.3