EPOXY/M SERIES WALK-BEHIND TROWEL — OPERATION AND PARTS MANUAL — REV. #5 (10/06/10) — PAGE 19
Figures 3 shows the location of the basic controls or components,
for the EPOXY/M SERIES trowel. Listed below is a brief
explanation of each control or component
1.
Quick Pitch™ Control Handle – To adjust the pitch of
the blades, grasp the handle then squeeze and either move
the handle forward or backward to achieve the desired
blade pitch.
2.
Throttle Control Lever – Controls the speed of the engine.
Move the hand lever towards the operator to increase
engine speed (high), away from the operator to decrease
engine speed (low).
3.
Hand Grip/Handle Bar – When operating the trowel, place
both hands on each grip to maneuver the trowel. Replace
hand grips when they become worn or damaged.
4.
Centrifugal Kill Switch – In the event the operator looses
control of the trowel, this switch will shut-down the engine.
5.
Engine – This trowel uses Honda, Robin and Briggs and
Stratton type gasoline engines.
6.
Auxiliary Lifting Tube - Use this tube to lift the trowel onto
a slab. Tube is to be inserted into socket located in front of
the gearbox.
7.
Pitch Control (standard models) - Turn this "Star Wheel"
clockwise for increase blade pitch, and counter-clockwise
for decrease blade pitch.
8.
Clutch Lever - Clutch engagement lever. When this lever
is engaged, the blades will begin to rotate. May be used
with either Quick Pitch™ or Standard handle.
9.
Main Tube - When disassembling components inside the
tube exercise extreme CAUTION! Tube is spring-loaded,
severe injury could result if not disassembled correctly.
10. Trowel Lifting Point – Insert the auxiliary lifting tube here.
See Figure 19.
11. AC Power Plug (Electric Models Only) – Insert this plug
into an AC power source.
12. Micro-Switch (Electric Models Only) – In the event the
operator loses control of the trowel, this micro-switch will
shut-down the electric motor.
13. Electric Switch Box (Electric Models Only) – Provides
AC power to the electric motor.
14. Guard Ring- NEVER! put hands or feet inside guard ring.
15. Electric Motor (Electric Models Only) – This trowel uses
a 2 HP, 115/230 VAC single phase electric motor.
16. Trowel Arm – NEVER operate the trowel with a bent, broken
or out of adjustment trowel arm. If the blades show uneven
wear patterns or some blades wear out faster than others,
the trowel arm may need to be adjusted. Use the trowel
arm adjustment tool P/N 1817 to adjust the trowel arms.
17. Blades – This trowel is equipped with combination blades.
These blades are versatile and should take care of most
troweling needs. In addition float discs can be attached to
the trowel arms that will allow the trowel to float on "wet"
concrete.
18. V-Belt Cover – Remove this cover to gain access to the V-
belt. NEVER operate the trowel with this cover removed.
19. Weights – The trowel may be equipped with two 10 lbs.
weights. The weights may be removed to reduce the
operating weight of the trowel.
20. Stabilizer Ring – Reduces trowel arm vibration. Helps
stabilize trowel arm.
EPOXY/M SERIES TROWEL— CONTROLS AND COMPONENTS
Summary of Contents for WHITEMAN EPOXY/M Series
Page 13: ...EPOXY M SERIES WALK BEHIND TROWEL OPERATION AND PARTS MANUAL REV 5 10 06 10 PAGE 13 NOTES...
Page 102: ...PAGE 102 EPOXY SERIES WALK BEHIND TROWEL OPERATION AND PARTS MANUAL REV 5 10 06 10 NOTE PAGE...
Page 105: ...EPOXY M SERIES WALK BEHIND TROWEL OPERATION AND PARTS MANUAL REV 5 10 06 10 PAGE 105 NOTE PAGE...