PAGE 10 — ST2037F/2040TF SUBMERSIBLE PUMP • OPERATION AND PARTS MANUAL — REV. #3 (12/14/17) 

is present, install the pump on a platform before operating.
This pump must always be positioned on a platform in an 

upright position. NEVER operate the pump by a suspended 

rope. To prevent large solids from entering the pump, install 

a wire mesh screen or similar barrier around the pump.
If the pump was used to pump water containing mud, silt, 

use clean water to flush out the pump after each use.
DO NOT allow the pump to run dry, as this will damage the 

pump. During maintenance, dry running is permissible but 

only for a few seconds.
NEVER lift the pump by its electrical power cord. ALWAYS 

lift the pump by its carrying handle or attach a rope to the 

carrying handle.
A pump fully submerged pump in liquid will not freeze, 

unless the liquid freezes. 

DO NOT allow a partially 

submerged pump to freeze. The expansion of water freezing 

in the volute may crack the pump, causing expensive 

repairs. If there is any danger of the pump being subjected 

to freezing temperatures, lift the pump from water and allow 

it to drain thoroughly.
If the pump jams or the pump rotor locks for any reason, 

disconnect the pump from the power source immediately.
Allowing the pump motor to cycle ON and OFF under an 

overload condition can burn out the motor.
When replacement of nuts and bolts is required, use only 

recommended parts as referenced in the parts section of 

this manual. This pump uses metric threads. 

DO NOT use 

English measurement threads.
Failure to follow the above referenced precautions could 

result in serious injury or death! Replace pump cord 

immediately if cord becomes damaged or severed. This 

pump must be installed in accordance with National Electric 

Code ANSI/NFPA 70 so as to prevent moisture from 

entering or accumulating with the boxes, conduit bodies 

fittings, float housing or cable.

  WARNING

Explosion or Fire Hazard exists if this 

pump is used with flammable liquids. DO 

NOT use this pump with flammable liquids. 

DO NOT install this pump in hazardous 

locations as defined by the National 

Electrical Code, ANSI/NFPA 70.

GENERAL INFORMATION

The Multiquip Model ST2037F and ST2040TF submersible 

pumps with a float switch are designed to pump water 

automatically. They are used for the draining (dewatering) 

of well casings construction sites, cofferdams, manholes, 

transformer vaults and excavations and are acceptable for 

indoor and outdoor use.
A Nitorile rubber over steel impeller is attached to the output 

shaft of a 1HP electric motor which provides adequate 

power for general purpose pumping. This submersible 

pump is supplied completely with an electric power cable 

which is equipped with a float switch and a discharge port 

located on top or on one side of the pump which accepts 

a 2-inch hose.
This pump is ideal for portability because of its light 

weight and carrying handle. For reliability and long life, a 

mechanical seal provides shaft sealing, with an oil chamber 

separating the pump section from the motor.
The pump when in use, should be installed as free standing 

(upright position) on its strainer base. A 2-inch discharge 

hose (not supplied) should be connected to the discharge 

port located on top or one side of the pump. The discharge 

hose should be adequately supported to avoid stress on 

the pump.
For maximum water flow, the discharge hose should be 

kept as short as possible, and with minimum elevation 

above the pump.
Remember, as the length and/or height of the discharge 

hose is increased, the flow of water will be reduced. Also 

any reduction in the hose size, and any fittings such as 

valves or outlet nozzles, will restrict the water flow.
To avoid back-siphonage when the pump is switched off, 

ensure that the end of the discharge hose is installed above 

the water level at the final discharge point.
When the pump is switched off, the water remaining in the 

hose will run back through the pump. This can be avoided 

by placing a non-return valve in the hose nearest the pump.
NEVER use this submersible pump to pump flammable 

liquids or operate in a explosive or flammable environment.
Avoid using this pump in conditions where mud, grit, silt 

or other debris are present. These conditions could cause 

blockage and cause excessive pump wear.
DO NOT install the pump directly into an area where there 

is a heavy buildup of mud, grit, silt, or debris. if this condition 

Discount-Equipment.com

Summary of Contents for ST2037F

Page 1: ...PARTS MANUAL THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES MODELS ST2037F ST2040TF SUBMERSIBLE PUMP WITH FLOAT SWITCH Revision 3 12 14 17 www discount equipment com D i s c o u n t E q u i p...

Page 2: ...ie Terex JLG MultiQuip Mayco Toro Stone Diamond Products Magnum Airman Mustang Power Blanket Nifty Lift Atlas Copco Chicago Pneumatic Allmand Brothers Essick Miller Spreader Skyjack Lull Skytrak Tsuru...

Page 3: ...eral Information 10 Pump Components 11 Float Switches 12 Installation 13 Operation 14 Maintenance 16 17 Troubleshooting 18 Performance Curve Wiring Diagram 19 Explanation Of Code In Remarks Column 20...

Page 4: ...ator and are preceded by one of four words DANGER WARNING CAUTION or NOTICE SAFETY SYMBOLS DANGER Indicates a hazardous situation which if not avoided WILL result in DEATH or SERIOUS INJURY WARNING In...

Page 5: ...area when the equipment is in operation DO NOT use the equipment for any purpose other than its intended purposes or applications NOTICE This equipment should only be operated by trained and qualifie...

Page 6: ...s manner may heat the oil in the seal cavity above the critical point causing pump damage DO NOT pump water with a temperature greater than 140 F 60 C DO NOT pump liquids containing acid or alkali ALW...

Page 7: ...th by electrocution can result from operating an ungrounded motor Control Box Safety DANGER ALWAYS have a qualified electrician perform the control box installation The possibility exists of electrica...

Page 8: ...g Amps 25 25 Running Amps 6 9 6 8 Thermal Overload Protection YES YES Rotation CCW Note 1 CCW Note 1 Mechanical Seal Oil Capacity 120 cc Note 2 133 cc Note 2 Check Frequency Monthly 300 hrs Monthly 30...

Page 9: ...37 mm 4 37 in 111 mm C 25 ft 7 6 m 7 08 in 180 mm D 15 74 in 400 mm 15 74 in 400 mm E 5 51 in 140 mm 5 51 in 140 mm F 3 23 in 82 mm 3 23 in 82 mm G 7 48 in 190 mm 7 08 in 180 mm H 1 63 in 41 5 mm 1 63...

Page 10: ...GENERAL INFORMATION The Multiquip Model ST2037F and ST2040TF submersible pumps with a float switch are designed to pump water automatically They are used for the draining dewatering of well casings co...

Page 11: ...ower cable which is equipped with a float switch Always check the cable for signs of wear NEVER use a defective power cable Replace the cable immediately if the cable is worn or defective 6 Carrying H...

Page 12: ...provides excellent resistance to nuisance trips due to fluid turbulence The case and cable are hermetically sealed via re injection molding Suitable for most liquid environments Hermetically sealed T...

Page 13: ...t Multiquip s Technical Support Department CAUTION When Installing the float switch keep enough space around the float switch to avoid an improper operation POWER CORD REQUIREMENTS When routing the 11...

Page 14: ...position the pump directly on a soft loose bottom Remember to attain maximum pumping capacity and prevent excessive wear position the pump so it will not burrow itself into sand or clay OPERATION Figu...

Page 15: ...echanical seal perform the following disassembly procedure then perform oil check Refer to Figure 11 for location of parts to be removed For Model ST2040TF 1 Position pump upside down 2 Remove casing...

Page 16: ...TEP 5 REMOVE LINER CASING COVER STEP 4 REMOVE IMPELLER STEP 6 REMOVE OIL PLUG AND PACKING STEP 2 REMOVE STRAINER OIL CAVITY REMOVE FILL PLUG AND VISUALLY INSPECT THAT OIL CAVITY IS FULL ENOUGH TO COVE...

Page 17: ...nsulation Insulation resistance must be greater than 15 megaohms If resistance is low disassemble pump motor and bake windings to dry them Defective motor and pump bearings Check for excessive bearing...

Page 18: ...NG DIAGRAM ST 2037F ST 2040TFSUB PUMP PERFORMANCECURVES AND WIRING DIAGRAM PAGE 17 ST 2037F ST 2040TF SUB PUMPS OPERATION PARTS MANUAL REV 1 05 25 15 PERFORMANCE CURVES Figure 11 Pump Performance Curv...

Page 19: ...e availability of the parts listed NOTICE When ordering a part that has more than one item number listed check the remarks column for help in determining the proper part to order QTY Column Numbers Us...

Page 20: ...RD WITH GLAND 1 020S500UL060 MECHANICAL SEAL 1 0201503A103 PACKING ST2040TF SUBMERSIBLE PUMP 1 to 3 units Qty P N Description 1 0202037F120 AC CORD WITH GLAND 1 020S500UL060 MECHANICAL SEAL 1 0202005T...

Page 21: ...AND PARTS MANUAL REV 3 12 14 17 ST2037F PUMP ASSEMBLY ST 2037F ELECTRIC SUBMERSIBLE PUMP ASSY PAGE 19 ST 2037F ST 2040TF SUB PUMPS OPERATION PARTS MANUAL REV 1 05 25 15 ST 2037F ELECTRIC SUBMERSIBLE...

Page 22: ...125 127 0202037F127 CARRYING HANDLE 1 129 020S2047129 FRAME COVER 1 131 020S2047131 BOLT 3 145 0202037F145 SET PIECE 1 146 020S500UL146 STRAINER 1 157 020S2047157 PACKING 1 170 020S500UL170 IMPELLER N...

Page 23: ...ND PARTS MANUAL REV 3 12 14 17 ST2040TF PUMP ASSEMBLY ST 2040TF ELECTRIC SUBMERSIBLE PUMP ASSY PAGE 21 ST 2037F ST 2040TF SUB PUMPS OPERATION PARTS MANUAL REV 1 05 25 15 ST 2040TF ELECTRIC SUBMERSIBLE...

Page 24: ...3121 121 1 0202037F1211 CORD CLAMP 1 123 0202037F123 CHAIN 1 125 0201503A125 SCREW 2 REPLACES P N 0201503125 127 020S500UL127 CARRYING HANDLE 1 129 020S2047129 FRAME COVER 1 131 020S2047131 BOLT 3 145...

Page 25: ...ie Terex JLG MultiQuip Mayco Toro Stone Diamond Products Magnum Airman Mustang Power Blanket Nifty Lift Atlas Copco Chicago Pneumatic Allmand Brothers Essick Miller Spreader Skyjack Lull Skytrak Tsuru...

Reviews: