PAGE 10 — ST2037F/2040TF SUBMERSIBLE PUMP • OPERATION AND PARTS MANUAL — REV. #3 (12/14/17)
is present, install the pump on a platform before operating.
This pump must always be positioned on a platform in an
upright position. NEVER operate the pump by a suspended
rope. To prevent large solids from entering the pump, install
a wire mesh screen or similar barrier around the pump.
If the pump was used to pump water containing mud, silt,
use clean water to flush out the pump after each use.
DO NOT allow the pump to run dry, as this will damage the
pump. During maintenance, dry running is permissible but
only for a few seconds.
NEVER lift the pump by its electrical power cord. ALWAYS
lift the pump by its carrying handle or attach a rope to the
carrying handle.
A pump fully submerged pump in liquid will not freeze,
unless the liquid freezes.
DO NOT allow a partially
submerged pump to freeze. The expansion of water freezing
in the volute may crack the pump, causing expensive
repairs. If there is any danger of the pump being subjected
to freezing temperatures, lift the pump from water and allow
it to drain thoroughly.
If the pump jams or the pump rotor locks for any reason,
disconnect the pump from the power source immediately.
Allowing the pump motor to cycle ON and OFF under an
overload condition can burn out the motor.
When replacement of nuts and bolts is required, use only
recommended parts as referenced in the parts section of
this manual. This pump uses metric threads.
DO NOT use
English measurement threads.
Failure to follow the above referenced precautions could
result in serious injury or death! Replace pump cord
immediately if cord becomes damaged or severed. This
pump must be installed in accordance with National Electric
Code ANSI/NFPA 70 so as to prevent moisture from
entering or accumulating with the boxes, conduit bodies
fittings, float housing or cable.
WARNING
Explosion or Fire Hazard exists if this
pump is used with flammable liquids. DO
NOT use this pump with flammable liquids.
DO NOT install this pump in hazardous
locations as defined by the National
Electrical Code, ANSI/NFPA 70.
GENERAL INFORMATION
The Multiquip Model ST2037F and ST2040TF submersible
pumps with a float switch are designed to pump water
automatically. They are used for the draining (dewatering)
of well casings construction sites, cofferdams, manholes,
transformer vaults and excavations and are acceptable for
indoor and outdoor use.
A Nitorile rubber over steel impeller is attached to the output
shaft of a 1HP electric motor which provides adequate
power for general purpose pumping. This submersible
pump is supplied completely with an electric power cable
which is equipped with a float switch and a discharge port
located on top or on one side of the pump which accepts
a 2-inch hose.
This pump is ideal for portability because of its light
weight and carrying handle. For reliability and long life, a
mechanical seal provides shaft sealing, with an oil chamber
separating the pump section from the motor.
The pump when in use, should be installed as free standing
(upright position) on its strainer base. A 2-inch discharge
hose (not supplied) should be connected to the discharge
port located on top or one side of the pump. The discharge
hose should be adequately supported to avoid stress on
the pump.
For maximum water flow, the discharge hose should be
kept as short as possible, and with minimum elevation
above the pump.
Remember, as the length and/or height of the discharge
hose is increased, the flow of water will be reduced. Also
any reduction in the hose size, and any fittings such as
valves or outlet nozzles, will restrict the water flow.
To avoid back-siphonage when the pump is switched off,
ensure that the end of the discharge hose is installed above
the water level at the final discharge point.
When the pump is switched off, the water remaining in the
hose will run back through the pump. This can be avoided
by placing a non-return valve in the hose nearest the pump.
NEVER use this submersible pump to pump flammable
liquids or operate in a explosive or flammable environment.
Avoid using this pump in conditions where mud, grit, silt
or other debris are present. These conditions could cause
blockage and cause excessive pump wear.
DO NOT install the pump directly into an area where there
is a heavy buildup of mud, grit, silt, or debris. if this condition
Discount-Equipment.com