QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 35
WIRING LOCATOR — CONTROL PANEL
PILOT LAMPS INDICATOR
I ) No Green or Red lights
PILOT LAMPS ALERTS
I ) Red light Flashing in 1 second intervals
Priming Failure.
Inspect hose for kinds, leaks, missing gaskets,
clogged strainer or lack of water.
Check float connections.
II ) Green and Red lights on Flashing in 0.5 sec interval
III) Red light Flashing 2 times, turns OFF for 3 seconds and repeats
Low fuel.
IV ) Red light Flashing 3 times, turns OFF for 3 seconds and repeats
Check electrical connections.
V ) Red light Flashing 5 times, turns OFF for 3 seconds and repeats
ECU error. Contact Multiquip for service.
Engine running.
Auto/Standby.
III ) Green light stays on
IV ) Green light Flashing in 1 second internals
II ) Green and Red lights on
Battery power supply is on.
No Battery power.