DCA-56SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/14/10) — PAGE 9
1
DCA-56SPX — SAFETY MESSAGE ALERT SYMBOLS
ALWAYS
place the
engine ON/OFF
switch (
MPEC
) in the
OFF/RESET
position when the generator is not in use.
ALWAYS
wear approved
respiratory
protection.
ALWAYS
wear approved
eye
and
hearing
protection.
Other important messages are provided throughout this
manual to help prevent damage to your generator, other
property, or the surrounding environment.
This generator, other property, or
the surrounding environment
could be damaged if you do not
follow instructions.
NOTE
NEVER
tamper with the factory settings
of the engine governor or settings.
Personal injury and damage to the engine
or equipment can result if operating in
speed ranges above maximum allowable.
CAUTION - OVER-SPEED CONDITIONS
CAUTION - ACCIDENTAL STARTING
CAUTION - RESPIRATORY HAZARDS
CAUTION - SIGHT AND HEARING HAZARDS
CAUTION - EQUIPMENT DAMAGE MESSAGES
NEVER
operate equipment with covers,
or guards removed. Keep
fingers
,
hands
,
hair
and clothing away from all moving
parts to prevent injury.
WARNING - ROTATING PARTS
Wet-Stacking is a common problem with diesel engines
which are operated for extended periods with light or no
load applied. When a diesel engine operates without
sufficient load (less than 40% of the rated output) it will
not operate at its optimum temperature. This will allow
unburned fuel to accumulate in the exhaust system, which
can foul the fuel injectors, engine valves and exhaust
system, including turbocharges, and reduce the operating
performance.
In order for a diesel engine to operate at peak efficiency it
must be able to provide fuel and air in the proper ratio and
at a high enough engine temperature for the engine to
completely burn all of the fuel.
Wet stacking does usually cause any permanent damage
and can be alleviated if additional load is applied to relieve
the condition. It can reduce the system performance and
increase maintenance. Applying an increasing load over a
period of time until the excess fuel is burned off and the
system capacity is reached usually can repair the condition.
This can take several hours to burn off the accumulated
unburned fuel.
CAUTION - ENGINE LOAD (WET-STACKING)
Summary of Contents for Power WHISPERWATT DCA-56SPX
Page 3: ...DCA 56SPX OPERATION AND PARTS MANUAL REV 1 04 14 10 PAGE 3 1 NOTE PAGE ...
Page 15: ...DCA 56SPX OPERATION AND PARTS MANUAL REV 1 04 14 10 PAGE 15 1 NOTE PAGE ...
Page 22: ...PAGE 22 DCA 56SPX OPERATION AND PARTS MANUAL REV 1 04 22 10 NOTE PAGE ...
Page 53: ...DCA 56SPX OPERATION AND PARTS MANUAL REV 1 04 14 10 PAGE 53 1 NOTE PAGE ...
Page 85: ...DCA 56SPX OPERATION AND PARTS MANUAL REV 1 04 14 10 PAGE 85 1 NOTE PAGE ...