![MULTIQUIP MAYCO LS300G Operation Manual Download Page 38](http://html1.mh-extra.com/html/multiquip/mayco-ls300g/mayco-ls300g_operation-manual_1855385038.webp)
PAGE 38 — MAYCO LS300G CONCRETE PUMP • OPERATION MANUAL — REV. #2 (09/09/19)
Remote Control Cable Operation (25 ft.)
The remote control cable (Figure 37) has the following
controls:
Pump ON/OFF
– Starts and stops the forward pumping.
Pump REV
– Starts pumping in reverse direction.
Connect the
remote control cable
(Figure 37) to the
receptacle labeled
remote
located on front of the digital
panel.
Figure 37. Remote Control Cable
Before the remote control cable can be used the pumping
volume rate must be set.
1. Start the pump as outlined in the pumping section of
this manual.
2. Place the
pumping control switch
in the
LOCAL
position.
3. Using the momentary volume control switch, adjust
the pumping rate (volume) to the desired strokes per
minute.
4. Once the desired pumping rate has been achieved,
place the
pumping control switch
in the
REMOTE
position.
REMOTE CONTROL CABLE UNIT
25 FT. CABLE
PUMP REV
PUMP ON/OFF
TO CONTROL BOX
CONNECTOR
OPERATION
Summary of Contents for MAYCO LS300G
Page 2: ...PAGE 2 MAYCO LS300G CONCRETE PUMP OPERATION MANUAL REV 2 09 09 19 PROPOSITION 65 WARNING...
Page 5: ...MAYCO LS300G CONCRETE PUMP OPERATION MANUAL REV 2 09 09 19 PAGE 5 NOTES...
Page 73: ...MAYCO LS300G CONCRETE PUMP OPERATION MANUAL REV 2 09 09 19 PAGE 73 NOTES...
Page 85: ...MAYCO LS300G CONCRETE PUMP OPERATION MANUAL REV 2 09 09 19 PAGE 85 HYDRAULIC SYSTEM DIAGRAM...