ga6HR/6HRS
60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (08/12/14) — pAgE 33
3. On the GFCI module (Figure 40), verify that the
green
POWER LED is
ON
.
Figure 40. GFCI Module (Green LED ON)
4. Also verify that the AC voltmeter is registering a voltage
reading as indicated by Figure 45.
5. Next, press the
TeST
button on the GFCI module and
verify that the
green
POWER LED turns
OFF
and the
red
FAULT LED turns
ON
.
Figure 41. GFCI Module (Red/Fault LED ON)
6. Also verify that the main circuit breaker switch trips to
the
OFF
position.
Figure 42. Circuit Breaker OFF (GFCI Test)
7. Verify that the AC voltmeter (Figure 43) on the
generator reads zero volts.
MANUAL RESET
P
O
W
E
R
F
A
U
L
T
GREEN
POWER
LED
MANUAL RESET
P
O
W
E
R
F
A
U
L
T
PRESS
RED
FAULT
LED
ON
OFF
mAINTENANCE
Figure 43. AC Voltmeter (Zero Volts)
8. To restore power, press the RESET button (Figure 44)
on the GFCI module and verify that the
red
FAULT LED
turns
OFF
and the green POWER LED should turn
ON
Figure 44. GFCI Module (Green LED ON Reset)
9. Verify that the AC voltmeter is registering a voltage
reading as indicated by Figure 45.
Figure 45. AC Voltmeter (120/240V)
120
240
V
MANUAL RESET
P
O
W
E
R
F
A
U
L
T
PRESS
GREEN
POWER
LED
120
240
V
NOTICE
It is recommended that the GFCI unit be tested when
the generator is initially taken out of the box. Then, the
generator should be tested daily at startup.
CAuTiON
The GFCI module is designed to interrupt power when
a ground fault exists to prevent injuries and shock
hazards.
dO NOT
operate the generator if this test fails.
Consult a qualified electrician for repair or replacement