PAGE 18 — GA-6HZ A.C. GENERATOR — PARTS & OPERATION MANUAL — REV. #4 (10/08/04)
Generator Storage
For storage of the generating set for over 30 days, the
following is required:
z
Drain the fuel tank completely.
z
Run the engine until the gasoline in the carburetor is
completely consumed
.
z
Completely drain the oil from the crankcase and refill
with fresh oil.
z
Remove the spark plug, pour 2 or 3 cc of SAE 30 oil
into the cylinder and crank slowly to distribute the oil.
z
Slowly rotate the engine a few times with the starter
Rope and install a new plug.
z
Pull out the starter rope slowly and stop at the
compression point.
z
Clean all external parts of the generating set with a cloth.
z
Cover the generating set and store in a clean, dry place.
GA-6HZ— PREPARATION FOR LONG -TERM STORAGE