page 32 — DCa25Usi 60 hz generaTor • operaTion anD parTs manUal — rev. #3 (07/19/11)
generatOr start-up prOcedure
BeFore sTarTing
1. Place the
main, g.F.C.i., and aux. circuit breakers (Figure
36)
in the oFF position prior to starting the engine.
Figure 36. Main, Aux. and GFCI
Circuit Breakers (OFF)
2. Connect the load to the
receptacles or the output
terminal lugs as shown in Figure 11. These load
connection points can be found on the output terminal
panel and the output terminal panel’s hard wire hookup
panel.
3. Tighten terminal nuts securely to prevent load wires
from slipping out.
4. Close all engine enclosure doors (Figure 37).
Figure 37. Engine Enclosure Doors
CaUTion
The engine’s exhaust contains harmful emissions.
alWaYs have adequate ventilation when operating.
Direct exhaust away from nearby personnel.
Warning
never manually start the engine with the main, gFCi
or auxiliary circuit breakers in the on (closed) position.
INCORRECT
CORRECT
sTarTing
1. Place the
voltage selector switch
in the desired
voltage position (Figure 38)..
Figure 38. Voltage Selector Switch
2. Preheat the engine glow plugs by turning the ignition
key (Figure 39) to the “OPERATION” position..
Figure 39. Ignition Switch
3. When the preheat lamp goes OFF (Figure 40), turn
the ignition key to the “start” position. Once the engine
starts, release the ignition key and allow it to return to
the “operation” position (Figure 39).
Figure 40. Pre-Heat Lamp
4. Once the engine starts, let the engine run for 1-2
minutes. Listen for any abnormal noises. If any
abnormalities exist, shut down the engine and correct
the problem.
5. The generator’s frequency meter (Figure 41) should be
displaying the 50 cycle output frequency in
herTz.
Figure 41. Frequency Meter
Summary of Contents for DCA5USI
Page 47: ...DCA25usi 60 hz Generator operation and parts manual rev 3 07 19 11 page 47 notes...
Page 50: ...page 50 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 GENERATOR ASSY...
Page 52: ...page 52 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 control box ASSY...
Page 54: ...page 54 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 control box ASSY...
Page 62: ...page 62 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 BATTERY ASSY...
Page 64: ...page 64 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 Muffler Assy...
Page 66: ...page 66 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 FUEL TANK ASSY...
Page 68: ...page 68 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 ENCLOSURE ASSY...
Page 74: ...page 74 DCA25Usi 60 hz Generator operation and parts manual rev 3 07 19 11 RUBBER SEALS ASSY...
Page 79: ...DCA25usi 60 hz Generator operation and parts manual rev 3 07 19 11 page 79 notes...