15
Short description of some selected functions
(all functions are described in the full version of the 22-23006 manual):
1. DISPLAY TEMP RESOLUTION:
This function determines the resolution of the displayed
temperature ( 0.5°C or 0.1°C ).
2. CONTROL ALGORITHM:
This function defines how to control the room temperature. Available
options are: ITLC for Underfloor Heating / Radiators / Electrical Heating (that
’
s advanced algorithm for
precise maintenance of room temperature), hyst/-0.5°C or +/-0.25°C, THB Actuator (option
recommended for systems with THB auto balancing actuators).
3.
S1/S2 INPUT:
A floor sensor, an external temperature sensor or an occupancy sensor can be
connected to the S1/S2 input of 22-23006RF. Additionally, by connecting a NO type of ON/OFF
voltage-free contact, you can use this input as a OneTouch rules trigger (programmed in the Salus
Smart Home app) or as a Heat/Cool changeover.
4.
VALVE PROTECTION:
This function activates all actuators once a week for 5 minutes (in summer,
this function helps to prevent the actuators stuck).
6.
MIN TURN OFF TIME:
Minimum switch-off time (thermostat will not send the signal for
heating/cooling more often than specified in this parameter).
7. OPTIMISATION FEATURE:
Optimum Start and Optimum Stop functions are energy saving feature
that makes thermostat most cost effective (in combination with ITLC control algorithm).
9.
DEVICE INFORMATION:
In this menu user can check: Software Version, RF range value, Paired
devices or also user can activate Identification mode.
*10. FACTORY RESET:
Here you can RESET your device to factory settings. After successfull reset
device will be removed from ZigBee network and you will need to add / pair your device again.
8.
COMFORT WARM FLOOR:
This function helps to keep the floor warm, even if the room is warm
enough and there is no need to turn on the heating. User can select 3 levels of warm floor feature.
Please note it is not an economy feature, as your heating system may be ON even if there is no heating
demand from the room thermostat. It is COMFORT feature which keeps your floor warm all the time.
5. INTERNAL RELAY (COM/NO):
Internal relay activation or deactivation with COM/NO outputs use. Default
is enable.
Français
D
eutsch
Neder
lands
English
Summary of Contents for 22-23006
Page 1: ...By QUICK GUIDE 22 23006...