Touchscreen Display 

 

When the controller is first powered on, the display will be blank for a few seconds as the system 
boots up.  The first screen displayed is shown only briefly at startup and contains the Multimetrixs 
logo controller model. 
 

 

Powerup splash screen 

 
Next, the main screen will be displayed.  The top button labeled “SAMPLE” is used to turn on and 
off the continuous display of the sensor raw magnitude and status information.  When the button 
is checked, the display will continually update.  Unchecking this button will stop updating the 
display and, in turn, allows more processing time available for the host serial connection. 
 

 

 

Initial main screen

 

Main screen while sampling on

 

 
 
The status information displayed at the bottom of the main screen has the following meaning: 
 
OK 

The controller initialized properly 

ERR 

The controller has encountered an error 

CONN 

The controller is wired to a host via the RS232 port 

ALONE 

There is no host wired to the RS232 port 

EXCLUSIVE 

The host has requested exclusive operation locking out the touchscreen 

CALIBRATED 

The sensor has been calibrated since powerup 

CALIBRATING…  The sensor is currently busy calibrating 
 
The button labeled “CALIB” is used to initiate calibration of the sensor.  Once pressed the screen 
will display the message “CALIBRATING PLEASE WAIT…”.  After about 15 seconds, the screen 
will display the message “CALIBRATION COMPLETE” or “CALIBRATION FAILED” along with the 
“OK” button.  The user should press this “OK” button to return to the main screen. 
 

Summary of Contents for MMXI-200

Page 1: ...Confidential www multimetrixs com Page 1 MMXI 200 Instruction Manual Rev 0 0 Preliminary 6 4 2008...

Page 2: ...sed on firmware version 1 0B CONTENTS Electrical Connections page 3 Setup page 4 Operation page 4 Touchscreen Display page 5 Serial Command Protocol page 7 Command Set page 7 Configuration commands pa...

Page 3: ...MMXI controller No other devices should be connected to any part of this port as it could damage the controller and or the connected device Using this port with anything other than the supplied Multi...

Page 4: ...e should be used with a host to convert this raw data into specific units of measurement such as film thickness In addition to what ever method is used by the user to calibrate and convert raw data to...

Page 5: ...ection Initial main screen Main screen while sampling on The status information displayed at the bottom of the main screen has the following meaning OK The controller initialized properly ERR The cont...

Page 6: ...diagnostics unitless G_TEMP Temperature of controller Celsius S_TEMP Temperature inside sensor Celsius STATUS See description of serial command XS 16 bit hex BAUD Host serial port baud rate bps To cha...

Page 7: ...base 10 variable length text format Integer parameters prefixed with 0x will be parsed as hexadecimal numbers If a command is prefixed with a lowercase letter x the return values if any will be in hex...

Page 8: ...nd mfal CR Response m CR Configuration loaded F CR Failed CR Syntax failure mfad Description Loads the factory default configuration settings into current working memory Command mfad CR Response m CR...

Page 9: ...XCS F CR Failed initiation CR Syntax failure XCQ Description Aborts the current calibration prior to completion Command XCQ CR Responses X CR Successfully aborted calibration F CR Failed execution CR...

Page 10: ...l temperature of the MMXI controller Value is in units of 1 16 degrees Celsius Divide the value by 16 to get Celsius Command XRTi CR Responses X s16 CR Successfully returns the temperature data F CR F...

Page 11: ...ever use any harsh detergents or solvents on any part of the controller or sensor The MMXI 200 Sensor Controller and the RST Sensor contain no user serviceable parts The user should never attempt to d...

Page 12: ...ill display text whenever an error occurs When this box is empty as shown above the error log is empty Clicking in the status box will pop up a window displaying the log of errors that have occurred C...

Page 13: ...ng with a firmware update With the Connected checkbox checked click on the menu item FILE Download Firmware This will start the download process The touchscreen display on the controller will go blank...

Page 14: ...Confidential www multimetrixs com Page 14 Mechanical Dimensions...

Page 15: ...Confidential www multimetrixs com Page 15 Notes...

Reviews: