22
Figure 36-1: Error tracking vs. time
Figure 37: Add license available in
Info tab
Figure 38: Pop-up window to add license
Figure 36-2: BER table measurements
After selecting the desired graph configuration, data will be plotted instantly (make sure to choose the
desired channel and click on the Start button).
You can access the instant and accumulated measurements data using the BER measurements table.
You can switch from graph to table measurements with no test interruptions. You can save the table
of result onto your desktop using the save button.
BER graphs and table measurements are displayed below in Figures 36 -1 and 36-2.
Platform Specific Measurements
MultiLane offers both emulated and real hardware FEC-supporting devices. Available FEC
measurements depend on the HW revisions and the type of BERT in use. In this section, the supported
specific measurements will be detailed.
Activating a purchased Real Hardware FEC License
To Enable FEC licensing, you can request FEC License by placing a Purchase Order to
by sending a screenshot of your BERT info tab.
After purchasing real hardware FEC license, you will be eligible for a license key (LK). This LK is
needed to unlock all real hardware FEC features.
After clicking on “Add License” availa
ble in Info tab, a pop-up window will appear, where your LK
should be copied and applied.