POWER REQUIREMENTS 

The HD3000 Series operates from 115 or 230 VAC with a wall-mount power supply or 9 to 24 
VDC @ >= 1A using a coaxial type connector (sleeve ground) on the rear panel labeled 

POWER

 

9~24VDC

. If desired, the units could be powered from a 12V battery. 

 
INSTALLATION 

The installation and start up of the HD3000 Series do not have special requirements. No 
special sequence must be followed to connect and start up the units. RG59 or other 75 Ohm 
Coax cable must be used for the BNC inputs and outputs and single mode fiber with the 
selected proper connectors must be used for the fiber link. Optionally, multimode fiber can be 
used with a shift patch on the transmitter, or if the units are ordered with MM optics, though 
significantly reduced range performance is expected for this scenario. The HD3000 Series 
come standard as stand-alone units. An optional rack-mounting kit is available to mount up to 
6 units in a 1 Rack-unit or 1 ¾” by 19” rack space. The part number is 

–RM6

 

SETTINGS FOR NON-SDI SIGNALS 

The HD3000 series comes configured to satisfy the needs of most users. 
This includes automatic reclocking and auto mute for SMPTE 3G, HD and SD signals and 
support for DVB/ASI.  
The factory setting is to auto mute the link when there is not a valid SMPTE signal present, 
and to attempt to reclock any signals that are close to the standard SMPTE rates of 270, 
1485 or 2970 MBPS. However, it is possible to pass other non SMPTE rates and digital 
signals by setting dip switches located inside the units to the non-default values. 
These settings are controlled by SW1. The settings are as follows: 
 

 
In the 

-1TX

, use settings for Ch 1. The Ch 2 settings are ignored. In the 

-1RX

 or 

-DR

, use 

settings for Ch 2. The Ch 1 settings are ignored. In the 

-TRX

, Ch 1 refers to the TX section 

and Ch 2 to the RX section. To access the switches, remove the 2 screws on the rear panel. 
Slide the pcb out. 
 

 

MAINTENANCE 

There are no user serviceable parts or internal adjustments other than the switch 
selections described above. As always, it is recommended that all optical fiber  
connections  be  checked  periodically  for  cleanliness  and  integrity.  For  repair  and  service, 
please call the factory. 
 

 

Sw 1 

Function 

Setting (Default values in Bold) 

Reclock Ch 1 

Off = reclock 

On = bypass 

Reclock Ch 2 

Off = reclock 

On = bypass 

Automute Ch 1 

Off = never mute 

On = automute  

Automute Ch 2 

Off = never mute 

On = automute 

 

 

 

Summary of Contents for HD-3000 Series

Page 1: ...HD3000 Gen2 Series SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT and DISTRIBUTION SYSTEM FOR HDTV and SDTV 191 FOREST AVENUE LOCUST VALLEY NY 11560 2132 USA 800 488 8378 516 671 7278 FAX 516 671 3362 sa...

Page 2: ...pyright 2013 MULTIDYNE Electronics Inc Locust Valley New York Printed in the United States of America All Rights Reserved Contents of this publication may not be reproduced in any form without the wri...

Page 3: ...REV C Feb 24 2015 TABLE OF CONTENTS INTRODUCTION 1 APPENDIX A BLOCK DIAGRAMS 4 APPENDIX B TECHNICAL SPECIFICATIONS 6...

Page 4: ...also include automatic cable EQ up to 120m for 3G and 350m for SD HD 3000 II Models include HD 3000 2TX Dual channel HDSDI to Fiber converter HD 3000 2RX Dual channel Fiber to HDSDI converter HD 3000...

Page 5: ...el will have 2 groups of Rate and STATUS LEDs one for each channel TRANSCEIVER HD3000 TRX The transceiver model designated by model number HD3000 TRX is essentially a 1TX and a 1RX in the same enclosu...

Page 6: ...eeds of most users This includes automatic reclocking and auto mute for SMPTE 3G HD and SD signals and support for DVB ASI The factory setting is to auto mute the link when there is not a valid SMPTE...

Page 7: ...Instruction Manual HD3000 Series 4 REV C Feb 24 2015 APPENDIX A Block Diagrams 1TX 2TX 1RX...

Page 8: ...Instruction Manual HD3000 Series 5 REV C Feb 24 2015 2RX TRX DR...

Page 9: ...or CWDM RX 1100 1600nm Optical Connector ST SC or LC Optical Source FP laser or CWDM DFB Optical Detector PIN Diode TX Output 7 Standard 0 DFB RX Sensitivity 22 dBm Link Margin 15 to 22 dB up to 40km...

Reviews: