5
•
Short press the “Menu” button to select the channel that needs to be configured
(MP740069 only). The tool identification display will indicate the chosen channel.
•
Press “Up” button to increase the required temperature or press “Down” to lower it
and the display will display the setting.
•
Press “1” button to select the preset 1 temperature for the chosen channel
•
Press “2” button to select preset 2 temperature.
•
Press “3” button to select preset 3 temperature.
Note:
the preset temperatures of 200/300/400
o
C can be amended in the settings menu.
SYSTEM SETTING
System Parameter Setting
•
Press and hold the “Menu” button until the loading function is complete.
•
If a passkey has been set, enter each digit by using “Up” or “Down” buttons then
press “Enter” to move to the next digit.
•
When the last correct digit is entered or if no passkey has been set, the System
Parameter menu is displayed.
•
Press “Up” or “Down” buttons to change the default settings and press “Enter” to
move to the next option.
•
Default unit is
o
C.
•
If a passkey is set, the ability to change any parameters including temperature
setting option is prevented unless the passkey is entered.
•
When the correct passkey is entered again in the parameter setting menu, the
passkey is cleared and operation is unlocked.
Channel Setting
•
The tool you wish to use on the channel must be connected, then press button
“1” or “3” for 2 seconds to select the channel (MP740069 model) to display the
settings for.
•
Do not connect or disconnect the soldering tool while in channel setting parameter
mode or damage may occur.
•
Press “Up” or “Down” buttons to change each of the default settings and press
“Enter” to move to the next option.
•
Factory default can be selected for each channel separately to restore all settings
to ‘as new’ condition.
1. Temp Offset: Used to compensate for any errors in the actual tip and the required
temperature of the soldering tool.
Compensation range: -50
o
C ~ +50
o
C, -90
o
F ~ +90
o
F. When the value is positive,
the tip temperature will increase according to the set value; when the value is
negative, the tip temperature will decrease according to the set value. The factory
default value is 0.
2. Standby Temp: The temperature of the iron when the system is under the standby
mode. When the iron is in standby mode, the maintained temperature is:
150°C / 302°F: the lowest standby temperature.
300°C / 572°F: the highest standby temperature allowed.
When the actual operating temperature is less than the user set standby
temperature, the product will enter the standby mode and maintain the actual
operating temperature. The factory default is: 150°C.