multicomp pro MP710079 User Manual Download Page 6

Page <6>

V1.0

14/06/22

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
sg.element14.com/b/multicomp-pro

Part Number

MP710079 

MP710079 US

MP710080 

MP710080 US

MP710081 

MP710081 US

Current Regulation

Load from 10% to 90% Variation

50mA

Line from 90 to 264V AC Variation

20mA

Ripple & Noise (peak to peak)

≤50mA

Switching Operation Frequency

50kHz to 150kHz

Aux output 1

Fixed 3.3 /5V DC. 1.8A cont. 2A Max.

Aux output 2

Fixed 12V DC, 800mA cont. 1A Max.

Power Factor

>0.9

Efficiency at Maximum Power

≥80.5%

Volt and Amp Control Type

Rotary Encoder

Voltmeter and Ammeter Display

4 Digit LCD

Voltmeter Accuracy

5 counts for range V<5V 

±0.2% +5 counts for range V≥5V

Ammeter Accuracy

15 counts for range I≤1A

±0.5% +6 counts for range I>1A

LCD Indication

CC, CV, Amp, Volt, Output ON-OFF, Aux output current

Protection

Short Circuit, Overload, Over Temperature, Tracking OVP

CE Approvals

LVD: EN 61010, EMC: EN 55011

Cooling System

Natural Convection

Dimensions (W×H×D)

70mm × 150mm × 250mm / 2.8″ × 6″ × 9.8″

Input Voltage (Universal input)

100V AC to 240V AC, 50Hz / 60Hz

Full Load Input Current at 230V AC

0.83A

Weight

2 kgs

Caution:

1. Use a grounded 3 pin AC source.
2. This unit is for indoor use only.
3. Do not operate or place this unit in a humid, dusty, in direct sunlight location or near any heat source.
4. Before plugging into local AC mains, check with the rating label at the back of the unit.
5. Do not block any ventilation openings of the unit.

6.  This unit must be used within the specified rating, regular excessive continuous loading may cause damage to the power 

supply.

7. The gauge size of input power cable must be at least 0.75mm2 and the total length of power cable must not exceed 3m.

Summary of Contents for MP710079

Page 1: ...com multicomp pro sg element14 com b multicomp pro User Manual Switching Mode Power Supply with USB Remote Control Part Number MP710079 MP710080 MP710081 MP710079 US MP710080 US MP710081 US MP710079...

Page 2: ...an provide 3 outputs at the same time All three outputs are fully isolated so different cross connections of 2 or 3 outputs can provide various fixed or variable output voltages Any output can be conn...

Page 3: ...current is less than the preset current limit ing value When the load current is equal to or greater than the preset current limiting value the power supply will automati cally cross over to the cons...

Page 4: ...ice that requires for example 3 or 5V 12 V or 12V and 1 36V as shown in Fig 1 The variable main output is set for 12V and it is assigned as the 12V source available maximum current 3A Note the variabl...

Page 5: ...decrease to zero to prevent damage to power supply When the temperature inside the power supply returns to normal then the power supply will automatically return to operation again PC Connection The N...

Page 6: ...dication CC CV Amp Volt Output ON OFF Aux output current Protection Short Circuit Overload Over Temperature Tracking OVP CE Approvals LVD EN 61010 EMC EN 55011 Cooling System Natural Convection Dimens...

Page 7: ...CR OK CR Get Setting Volt Curr voltage 0 3640 current 0 5100 Input Command GETS CR Return Value 500 1000 CR OK CR Meaning The Memory setting voltage value is 5 00V and Current is 1 000A Input Command...

Page 8: ...ability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to limit or restrict the Group s liability for death...

Reviews: