Tracking Output Over Voltage Protection (OVP)

This is to protect the connected load in the event that the output voltage control circuit malfunctions, the maximum output volt

-

age will not exceed 30% of the adjusted voltage value at the time of the operation.

Over Temperature Protection

When the temperature inside the power supply becomes higher than a pre-determined value, the output voltage and current 

of the power supply will automatically decrease to zero to prevent damage to power supply. When the temperature inside the 

power supply returns to normal then the power supply will automatically return to operation again.

PC Connection

The NTP with USB can be remote control using Windows PC. Connecting the NTP to PC using provided USB cable as fol

-

lowing connection diagram.

For the detail usage of driver and PC software.

Specifications

Part Number

MP710079 

MP710079 US

MP710080 

MP710080 US

MP710081 

MP710081 US

Output Voltage Range

1V DC to 20V DC

1V DC to 36V DC

1V DC to 60V DC

Output Current Range

0.25A to 5A

0.25A to 3A

0.25A to 1.6A

Voltage Regulation

Load from 10% to 90% Variation

70mV

70mV

70mV

Line from 90 to 264V AC Variation

25mV

Ripple & Noise (peak to peak)

≤120mV

≤150mV

≤180mV

Summary of Contents for MP710079

Page 1: ...com multicomp pro sg element14 com b multicomp pro User Manual Switching Mode Power Supply with USB Remote Control Part Number MP710079 MP710080 MP710081 MP710079 US MP710080 US MP710081 US MP710079...

Page 2: ...an provide 3 outputs at the same time All three outputs are fully isolated so different cross connections of 2 or 3 outputs can provide various fixed or variable output voltages Any output can be conn...

Page 3: ...current is less than the preset current limit ing value When the load current is equal to or greater than the preset current limiting value the power supply will automati cally cross over to the cons...

Page 4: ...ice that requires for example 3 or 5V 12 V or 12V and 1 36V as shown in Fig 1 The variable main output is set for 12V and it is assigned as the 12V source available maximum current 3A Note the variabl...

Page 5: ...decrease to zero to prevent damage to power supply When the temperature inside the power supply returns to normal then the power supply will automatically return to operation again PC Connection The N...

Page 6: ...dication CC CV Amp Volt Output ON OFF Aux output current Protection Short Circuit Overload Over Temperature Tracking OVP CE Approvals LVD EN 61010 EMC EN 55011 Cooling System Natural Convection Dimens...

Page 7: ...CR OK CR Get Setting Volt Curr voltage 0 3640 current 0 5100 Input Command GETS CR Return Value 500 1000 CR OK CR Meaning The Memory setting voltage value is 5 00V and Current is 1 000A Input Command...

Page 8: ...ability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to limit or restrict the Group s liability for death...

Reviews: