MP60608

MP60607

40.00A
400.0A

60.00A
600.0A

0.01 A

0.1 A

±(

2%+5)

MP60608

MP60607

400.0mV

4.000V
40.00V
400.0V

600V

600.0mV

6.000V
60.00V
600.0V

0.1mV

0.001V

0.01V

0.1V

1V

±( .

0 7

3

±( .

0 5

2

MP60608

MP60607

4.000V
40.00V
400.0V

600V

6.000V
60.00V
600.0V

0.001V

0.01V

0.1V

1V

0.01Hz

0.01kHz

±( .

1 0

5

±( .

0 8

5

±( . %+ )

0 5 2

Voltage Frequency

10Hz 60KHz

0 1

. Ω

0 001V

.

400.0Ω/600.0Ω

4.000V/6.000V

MP60608

MP60607

400.0Ω

4.000kΩ
40.00kΩ
400.0kΩ

4.000MΩ
40.00MΩ

600.0Ω

6.000kΩ
60.00kΩ
600.0kΩ

6.000MΩ
60.00MΩ

0 1

. Ω

0 001K

.

Ω

0 01K

.

Ω

0 1K

.

Ω

0 001M

.

Ω

0 01M

.

Ω

±( .

+

1 0

2

±( .

+

0 8

2

±( . %+ )

2 5 5

MP60608

MP60607

40.00nF
400.0nF
4.000uF
40.00uF
400.0uF

4.000mF
40.00mF

60.00nF
600.0nF
6.000uF
60.00uF
600.0uF

6.000mF
60.00mF

0.01nF

0.1nF

0.001μF

0.01μF

0.1μF

0.001mF

0.01mF

±( %+ )

4 5

±

%

10

10Hz

10MHz

0.01Hz

0.01MHz

±

(

0

.

1

%+

4

)

10.9 NCV

NCV

EFLo

EFHI

-

40

℃~

40

40

℃~

500

500

℃~

1000

-

40

℉~

104

104

℉~

932

932

℉~

1832

±

4

±(

1

.

5

%+

5

)

±(

2

.

0

%+

5

)

±

6

±(

2

.

0

%+

6

)

±(

2

.

5

%+

4

)

1

1

9.5 NCV AC Electric Field Sensing 

 

(Picture 6a)

The electric field sensing sensitivity is divided into two levels 

(“EFHI” and “EFLo”). The meter defaults to “EFHI”. Users can select 

different sensitivity levels according to the intensity of the measured 

electric field. Select "EFHI" of NCV when electric field is around 220V 

AC 50Hz/60Hz. Bring the NCV sensing end close to a charged electric 

field (socket, insulated wire, etc.). The LCD will display the segment 

"-" with beeps and red LED flashing. As the intensity of the measured 

electric field increases, the more segments (----) display , the higher 

frequency of buzzer beeps and LED flashes. Select “EFLo” when the 

electric field is around 110V AC 50Hz/60Hz. 

       Caution:

Use the NCV sensing end to approach measured electric field, 

otherwise the measurement sensitivity will be affected. When the 

measured electric field voltage is over 100V AC, observe whether the 

conductor is insulated to avoid personal injury. 

9.6 Others

    Auto power off: The meter will automatically power off to save power 

    if there is no operation for 15 min. You can wake it up by pressing 

    any button or restart it after turning the switch to OFF.

    Press and hold the SELECT button in off state and then turn on the 

    meter again to disable the auto power off function. Restart the meter 

    after shut it down to resume this function. 

    Buzzer: When any button is pressed or the function switch is turned, 

    if it is valid, the buzzer will make one beep (about 0.25s). The buzzer 

    will also beep intermittently to indicate the over range during the 

    voltage or current measurement. 

    Low battery detection: The battery voltage will be automatically 

    detected as long as the meter is on. If it is lower than 2.6V, the LCD 

    will display the “       ” symbol.

    Low battery shutdown function: When the battery voltage is lower 

    than 2.5V, the LCD displays the “       ” symbol, the “Lo.bt” interface 

    appears and lasts for about 10s, the buzzer makes consecutive 

    beeps 3 times, and then the meter automatically shuts down (no  

    

is displayed).

interface 

11. Technical Specifications

Accuracy: ± (%r counts), the calibration period is 1 year. 
Ambient temperature and humidity: 23°C±5°C; 

80%RH. 

Temperature coefficient: the accuracy assured temperature condition 

is 18°C-28°C, the range of ambient temperature fluctuation is stable 

within ±1°C. When the temperature is less than 18°C or over 28°C, 

the additional temperature coefficient error is 0.1 x (specified 

accuracy)/°C. 

10.1 Current Measurement 

AC Current

Range

Resolution

Accuracy

      

Caution: 

     

Accuracy guarantee range: 5%~100% of range

     

When the measured current reaches the warning value, there

 

will 

     

be an alarm sound (

MP60607

: 410A, 

MP60608

: 610A) 

     

With DC current DCA mode, LCD may display non-zero value

 

in

    

 open circuit state, users can press "REL" button to clear display      

 

     

to zero before each measurement. 

10.2 Voltage Measurement

DC Voltage

Range

Resolution

Accuracy

AC Voltage/Voltage Frequency 

Range

Resolution

Accuracy

      Caution: 

    

MP60607

: short press "SELECT” in AC voltage/Hz scale to enter

    

the Hz

 F

unction;

    

MP60608

: long press "SELECT" to enter/exit the Hz function, the 

    

input

 

range over 5V. 

    

The input impedance is about 10M

Ω

    

Current/voltage frequency response: 45Hz ~ 400Hz, displays true RMS 

    

value

    

Accuracy guarantee range: 1%~100% 

    

AC crest factor of non-sinusoidal wave can reach 3.0 at 4000 counts 

    

while can only reach 1.8 at 6000 counts, the additional error should be 

    

added for the corresponding crest factor as follows:

    

A. Add 3% when the peak factor is 1 ~ 2

    

B. Add 5% when the peak factor is 2 ~ 2.5

    

C. Add 7% when the peak factor is 2.5 ~ 3

10.3 Continuity/Diode Measurement

Function

Range

Resolution

Accuracy

10Ω: Consecutive beeps

≥31Ω: No beep

The median: uncertain
The open circuit voltage is 

about 4V 

For the silicon PN junction 

diode, the voltage value is 

generally about 0.5~0.8V.

10.4 Resistance Measurement

Range

Resolution

Accuracy

      

  Caution: 

     

Measured resistance value = displayed value – resistance value 

      

of short circuited test leads 

      

Open circuit voltage is about 1V 

      

Overload protection: 600Vrms

10.5 Capacitance Measurement

Range

Resolution

Accuracy

      Caution: 

    

Measured value = displayed value - open circuit value of the test leads 

    (For capacitance 

100nF, “REL” mode is recommended, open circuit 

     has residual reading). The guaranteed accuracy is 1%~100%. 

     

Overload protection: 600Vrms

10.6 Frequency Measurement

Range

Resolution

Accuracy

       Caution:

Measurement sensitivity: 
     

100kHz: 200mVrms

≤ 

input range

30Vrms; 

>100kHz~1MHz: 600mVrms

≤ 

input range

30Vrms; 

>1MHz~10MHz: 1Vrms

≤ 

input range

30Vrms. 

Duty ratio is only applicable to 

10kHz square wave measurement 

with a range of 1Vp-p: 

If frequency

1kHz, duty cycle will be 10.0%-95.0%; 

If frequency>1kHz, duty cycle will be 30.0%-70.0%. 

10.8 Temperature Measurement (

MP60608

 only)

Range

Resolution

Accuracy

       

Caution:

The meter displays "OL" after startup, it is only suitable for K-type 

thermocouple (Nickel-Chromium ~ Nickel-Silicon temperature 

sensor) and temperature measurements below 1000°C/1832°F. 

The formula for Celsius to Fahrenheit is °F =1.8°C + 32. 

Range

Electric field 

sensing 

sensitivity level

Accuracy

The electric field sensing sensitivity 

is divided into two levels (“EFHI” & 

“EFLo”). The meter defaults to “EFHI”. 

a) AC voltage above 24V±6V can be 

sensed. "EFLo" mode is recommended 

when the power frequency voltage is 

110V. 

b) "EFHI" can be set in 220V condition. 

AC voltage above 74V±12V can be 

sensed with getting close to wires, 

and identify whether the main socket 

is charged or to judge the live/neutral 

wire of socket according to the intensity 

of sensing. 

Note: Test results may be affected by 

different socket designs or wire I

nsulation thickness. 

11. Maintenance

Warning: Before opening the rear cover of meter , remove test

leads to avoid electric shock.

11.1 General Maintenance

      

Clean the meter casing with a soft cloth and mild detergent. Do 

     not use abrasives or solvents! 

      

Do not use the tester or test leads if they appear to have any 

      

abnormality. 

      

The maintenance and service must be implemented by qualified 

      

professionals or designated departments. 

11.2 Battery Replacement (Picture 7) 

When the “       ” symbol appears on the LCD, please replace the 

batteries in time to ensure measurement accuracy. Batteries 

specification: 

2 standard AAA 1.5V batteries. 

Operation

      

Turn off the meter and remove the test leads from the input terminals. 

      

Unscrew the screw of the battery compartment, remove the battery 

     cover, and take out the used batteries as shown. 

      

Replace the 2 standard AAA batteries according to the polarity 

     indication. 

MP60608

MP60607

40.00A
400.0A

60.00A
600.0A

0.01 A

0.1 A

±(

2%+5)

DC Current

Range

Resolution

Accuracy

Picture 7

Picture 6a

10.Probe usage

TESTING IN CAT III MEASUREMENT LOCATIONS

Ensure the test lead shield pressed firmly in place. Failure to use 

the CAT III shield increases arc-flash risk.

TESTING IN CAT II MEASUREMENT LOCATIONS

CAT III shields may be removed for CAT II locations. This will allow 

testing on recessed conductors such as standard wall outlets. 

Take care not to lose the shields.

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT. 

When this product has reached the end of its life it must be treated as Waste Electrical & Electronics 
Equipment (WEEE).    Any WEEE marked products must not be mixed with general household waste, 

but kept separate for the treatment, recovery and recycling of the materials used.    Contact your local 

authority for details of recycling schemes in your area. 

Made in China 

LS12 2QQ 