KF
7
Innovation. Quality. Performance. Best in Industry. Worldwide.
Set Surface
(Z=0)
The Set Surface function allows the operator to identify and set the surface of the material or the software Z
reference point as the Z-axis Home (Z=0)
when the plasma system is equipped with an oxyacetylene torch,
scribe, or similar attachment.
Traditional plasma systems do not require the operator to set the surface
.
1. Press
Jog Arrows
to position the oxyacetylene torch, scribe, or similar attachment
anywhere over the material.
2. Press
Set Surface
.
3. Enter the number corresponding to the attachment (e.g., 2 for oxyacetylene torch) using the number keypad.
4. Press
Enter
to select the tool.
5. Press
Z-axis Jog Arrows
to lower the head assembly until the attachment is just above the surface
of the table. The operator should monitor the Jog speed when lowering the Z-axis as the attachment could
crash into the material or the surface and break.
6. Press
Enter
to recognize the surface.
Routers * Lasers * Plasma * Water Jets * Knife Cutters