  14  /  15 

 

BLUETOOTH FUNCTION 

*M-1141X and M-1141XR have Bluetooth communication function (Bluetooth-4.2 
Class2) 
*With the dedicated application "Multi-Tracer" on the smartphone side, it is able to 
check measuring data and save the measurement results. 
*At the power-on, the Bluetooth function is off. For the communication, press 

“Bluetooth

/ Light

” button to activate the Bluetooth connection

. (If it took more than 3-

minutes to pair with 

“M

ulti-Tracer

”, t

he Bluetooth function is automatically turns-off. 

After about 30-minutes with no switch operation, the auto power-off function works.) 
*If your mobile device is an iPhone, iPad, etc., 

download “Multi

-

Tracer” 

from the App 

Store, and install. For Android devices, download 

Multi-Tracer

” from Google Play and 

install. App-Store requires Apple ID. Google-Play requires Google account. 
*For information of each account, communicate with a dedicated supplier of each 
mobile device. 
 
 
 
 

ATTENTION

 

*This product has a low power data communication system based on the Radio Law. 
(Built-in equipment; EYSHCN: 001-A10745) 
*The communication range depends on the surrounding environment such as other 
radio waves and devices. 
*This product uses communication frequencies of the 2.4 GHz band. If another wireless 
devices are using similar communication frequencies near this product, it may disturb 
wireless communication of both devices. Radio-wave interference may occur. In this 
case, stop other wireless devices or change the place where this product is used to avoid 
radio-wave interference. 

*”

Multi-Tracer

 is free of charge. However, the internet connection fee is different for 

downloading or using the apps. 
*The Bluetooth communication function may not works on all mobile terminals. 

*”

Multi-Tracer

” may not w

ork on all mobile devices. 

 
**Use of devices with radio-communication requires approval in the country of use, and 
use of the instrument in a country or a region may be subject to penalty as a violation 
of their laws. 

Summary of Contents for M-1141

Page 1: ...design Before using your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions With proper use and care your tester will give you years of sati...

Page 2: ...r rigorous in house inspection but we will repair free of charge if the cause of the failure is determined to be our responsibility such as a manufacturing defect The warranty period for this product...

Page 3: ...e agreement with the company Android and Google Play are trademarks of Google LLC The iOS trademark is used under a license agreement with Cisco Systems Inc USA iPhone iPad iPad mini and iPod Touch ar...

Page 4: ...type leakage current meter that greatly improved convenience using the latest technology Features Since the influence from the external magnetic field is slight a minute current can be measured accur...

Page 5: ...0A 5 0 rdg 5dgt 0 zero is displayed for values of 10 counts or less of each range Crest factor 2 Temperature and Humidity measurement accuracy reference value Displayed by Multi Tracer M 1141XR M 1141...

Page 6: ...le Standards EMC IEC 61326 1 Safety IEC 61010 1 EN 61010 RoHS Directive Battery 1pc of coin type lithium battery CR2450 Duration continuous use between 23 5 C reference value only M 1141 About 36 hour...

Page 7: ...ange Normal Data Hold MAX Hold Normal and so on repeating each time MAX Hold Maximum Hold Press DH MAX switch twice during both normal mode and filter mode and display MAX on LCD It holds a maximum me...

Page 8: ...8 15 smartphone connected via Bluetooth...

Page 9: ...le Bluetooth is on To transfer a displayed value to the dedicated Multi Tracer By pressing and holding for 1 second it turns on off the backlight 5 Liquid Crystal Display LCD To display measurements u...

Page 10: ...pairing functions Blinks while for pairing with the dedicated application Multi Tracer Lights up while the instrument is paired with Multi Tracer Off while Bluetooth pairing is not functioning APO aut...

Page 11: ...hillips screwdriver WARNING To prevent electric shock The battery cover must be reinstalled after replacing the batteries Do not use the instrument with the battery cover removed Do not replace the ba...

Page 12: ...current measurements Not at grounding conductor for single phase two wire system clamp 2 wires together for single phase three wire and three phase three wire systems clamp three wires all together D...

Page 13: ...range only Press Range button and set to the manual range mode Press DH MAX button twice to activate While MAX is displayed on the LCD it holds a maximum reading value Press DH MAX button again to rel...

Page 14: ...icated supplier of each mobile device ATTENTION This product has a low power data communication system based on the Radio Law Built in equipment EYSHCN 001 A10745 The communication range depends on th...

Page 15: ...he calibration procedure has been good enough within the tolerance regulated in our specification below Name of Model AC currents clamp tester Model Number M 1141 M 1141X M 1141XR Confirmed Accuracy R...

Reviews: