1.1 GENERAL 

  Qualified ALTINEX service personnel, or their 

authorized representatives must perform all 
service. 

1.2 INSTALLATION 

  To prevent fire or shock, do not expose this unit 

to rain or moisture. Do not place the 

MT107-100 

in direct sunlight, near heaters or heat radiating 
appliances, or near any liquid. Exposure to 
direct sunlight, smoke, or steam can harm 
internal components. 

 Handle 

the 

MT107-100 

carefully. Dropping or 

jarring can damage the card. 

  Do not pull the cables that are attached to the 

MT107-100.

 

  Insert the card carefully into the slots of the 

Multi-Tasker™ without bending any edges.  

1.3 CLEANING 

  Clean only the connector area with a dry cloth. 

Never use strong detergents or solvents, such 
as alcohol or thinner. Do not use a wet cloth or 
water to clean the card. Do not clean or touch 
any component or PCB. 

1.4 FCC / CE NOTICE 

  This device complies with part 15 of the FCC 

Rules. Operation is subject to the following two 
conditions: (1) This device may not cause 
harmful interference, and (2) this device must 
accept any interference received, including 
interference that may cause undesired 
operation. 

  This equipment has been tested and found to 

comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable 
protection against harmful interference when the 
equipment is operated in a commercial 
environment. This equipment generates, uses, 
and can radiate radio frequency energy and, if 
not installed and used in accordance with the 
instruction manual, may cause harmful 
interference to radio communications. Operation 
of this equipment in a residential area is likely to 
cause harmful interference in which case the 
user will be required to correct the interference 
at his own expense. 

  Any changes or modifications to the unit not 

expressly approved by ALTINEX, Inc. could void 
the user’s authority to operate the equipment. 

Summary of Contents for MT107-100

Page 1: ...MULTI TASKER MANUAL PART NUMBER 400 0351 002 64X64 MATRIX SWITCHER FOR MULTI TASKER USER S GUIDE MT107 100...

Page 2: ...N DIAGRAM 5 DIAGRAM 1 TYPICAL CONFIGURATION 5 DIAGRAM 2 OUTPUT CARD SWITCHES 6 DIAGRAM 3 ADD ON CARD SWITCHES 7 DIAGRAM 4 INTERNAL VIEW 8 INSTALLING YOUR MULTI TASKER 9 OPERATION 9 RS 232 CONTROL 9 DE...

Page 3: ...ts such as alcohol or thinner Do not use a wet cloth or water to clean the card Do not clean or touch any component or PCB 1 4 FCC CE NOTICE This device complies with part 15 of the FCC Rules Operatio...

Page 4: ...nts The proper selection of configuration can be achieved using MTSetup The switching elements within the Matrix Switcher are available in steps of 16 This is possible through the modular design of th...

Page 5: ...MULTI TASKER 4 PRODUCT DESCRIPTION 4...

Page 6: ...MULTI TASKER 5 APPLICATION DIAGRAM 5 DIAGRAM 1 TYPICAL CONFIGURATION...

Page 7: ...285 0420 002 OUTPUT CARD 1 800 ALTINEX www altinex com 6V 13V P28 P29 13V 6V 13V 6V P31 P30 P32 13V 6V 13V 6V C36 R22 C6 C22 R57 C35 R35 R69 R6 R44 C61 13V 6V C57 C85 C21 R21 C5 U11 C96 R20 C38 C4 C20...

Page 8: ...SW2 U6 R27 R11 R58 R25 SW4 R9 S C28 V U5 V R93 R96 R77 C5 C7 C26 C40 U12 C68 C53 C67 1 C94 R26 C10 R8 R54 R70 R36 C23 R46 C63 C52 U11 C64 C8 C95 C39 R24 R6 R57 R69 R35 C21 C36 R44 R94 S SW1 U4 R23 R7...

Page 9: ...MULTI TASKER 8 DIAGRAM 4 INTERNAL VIEW MT107 100 64X64 MATRIX ENGINE IDC IDC MAIN MP POWER SUPPLY IN1 OUT1 OUT2 IN2 IN4 IN3 OUT4 OUT3 IN62 IN64 IN63 IN61 OUT62 OUT63 OUT64 OUT61 64X64 MATRIX...

Page 10: ...uter control system or any other device capable of sending RS 232 commands 7 1 1 RS 232 INTERFACE The RS 232 commands for the MT107 100 are in a simple ASCII character format 1 Square brackets are par...

Page 11: ...one and the channel spacing is zero All 64 channels are ON the input audio level is set to the maximum of 32 and each input is connected to its corresponding output 3 MAT This command sets the matrix...

Page 12: ...the main Output Connector Card LEFT to RIGHT The following table illustrates the card and channel numbering The channel numbering is based upon the default configuration The default configuration is...

Page 13: ...d when the matrix is defined using the MAT S command Command Format MjCnUiS j Matrix ID j from 1 to 9 Cn Engine Card Slot Number Ui Unit ID i from 0 to 9 S Save Example In order to make configuration...

Page 14: ...and receive the following feedback 1 32 64 11 OUT S This command returns the input that is connected to the specified output Command Format OUTmSCnUi mm Output 2 digit from 01 to 64 Cn Engine Card Slo...

Page 15: ...for examples 16 SEL with and This command is the volume select command It sets the path to adjust the input volume level of the current matrix and is used in conjunction with the and commands Command...

Page 16: ...2 digit from 01 to 64 Cn Engine Card Slot Number Ui Unit ID i from 0 to 9 Example CHECK ONE OUTPUT Check for a signal on Output 1 of the Engine in slot 8 by sending the command SDO01C8 If a signal pr...

Page 17: ...tem will display the results This feedback will be similar to the following example MEMORY IC TEST RESULTS MEMORY IC PASS 24 HELP This command displays information available for the Multi Tasker inter...

Page 18: ...om 1 8 Ui Unit ID i from 0 9 Example Group 5 of Unit ID 1 contains the cards in slots 1 2 and 19 Read the member data for group 5 of Unit ID 1 Send the command RDG5U1 and receive the following feedbac...

Page 19: ...the other card s LED lights in that slot If it lights then the original card may be the source of the problem Call ALTINEX at 714 990 2300 8 2 LED IS BLINKING RED Cause 1 The CPU on the card is not w...

Page 20: ...ease call Altinex at 714 990 2300 ALTINEX POLICY 9 9 1 LIMITED WARRANTY RETURN POLICY Please see the Altinex website at www altinex com for details on warranty and return policy 9 2 CONTACT INFORMATIO...

Reviews: