MULTI-TASKER™
12
Example 2:
Inputs = 16
Outputs = 16
Input Offset = 00
Output Offset = 00
Width = 02
Spacing = 00
In this configuration, if Input 1 is connected to
Output 16, the entire channel, 1a and 1b, will be
switched to outputs 16a and 16b respectively.
Input Cards Output
Cards
4 3 2 1 1 2 3 4
13a 9a 5a 1a
1a 5a 9a 13a
13b 9b 5b 1b
1b 5b 9b 13b
14a 10a 6a 2a
2a 6a 10a 14a
14b 10b 6b 2b
2b 6b 10b 14b
15a 11a 7a 3a
3a 7a 11a 15a
15b 11b 7b 3b
3b 7b 11b 15b
16a 12a 8a 4a
4a 8a 12a 16a
16b 12b 8b 4b
4b 8b 12b 16b
4.
[M
j
C
n
]
This command selects the matrix to be active.
Command Format: [MjCnUi]
j
= Matrix ID (j = # from 1 to 9)
Cn = Engine Card Slot Number
Ui = Unit ID (i = # from 0 to 9)
Example:
There is a matrix engine in slot 6. Send the
command [M1C6] to recall matrix configuration
#1 of card 6.
5.
[M
j
C
n
S]
This command will save the defined matrix
number as the default, which would be recalled
on power up or reset. The matrix settings MUST
first be saved when the matrix is defined using
the [MAT…S] command
Command Format: [MjCnUiS]
j
= Matrix ID (j = # from 1 to 9)
Cn = Engine Card Slot Number
Ui = Unit ID (i = # from 0 to 9)
S =
Save
Example:
In order to make configuration #1 of card 6 the
default configuration when power is turned on,
send the command [M1C6S].
6.
[ON]
This command turns ON a single output, or all
the outputs, for the current matrix.
Command Format: [ONzzCnUi]
zz = Output Number (zz = # from 01 to 64)
Cn = Engine Card Slot Number
Ui = Unit ID (i = # from 0 to 9)
Example 1: SINGLE OUTPUT
There is an
MT107-100
in slot #10. Turn ON
output number 64 by sending the command
[ON64C10].
Example 2: ALL OUTPUTS
There is an MT107-100 in slot #10. Turn ON
ALL outputs by sending the command [ONC10].
7.
[OFF]
This command turns OFF a single output, or all
outputs, for the current matrix.
Command Format: [OFFzzCnUi]
zz = Output Number (zz = # from 01 to 64)
Cn = Engine Card Slot Number
Ui = Unit ID (i = # from 0 to 9)
Example 1: SINGLE OUTPUT
There is an
MT107-100
in slot #10. Turn OFF
only output number 01 by sending the command
[OFF01C10].
Example 2: ALL OUTPUTS
There is an
MT107-100
in slot #10. Turn OFF
ALL outputs by sending the command
[OFFC10 ].