Muller MISG-IO Operating Manual Download Page 3

MISG-IO-M

!

!
i

- This operating manual gives important handling instructions for the strain gauge amplifier. Compliance with all
   safety and handling instructions in this manual is a requirement for safe work.

- Qualified personnel must have read and understood this operating manual before mounting and start-up of the
  sensor.

- This operating manual is part of the product. Please keep this manual at a place accessible for all users and on-

site.

- Please comply with the local regulations and safety instructions for the field of application of this sensor.

- If the serial number on the product label becomes illegible (e.g. through mechanical damage), traceability can 

not be ensured.

- The strain gauge amplifier MISG-IO described in this manual is carefully designed and manufactured using 

state-of-the-art technology. Every component undergoes strict quality inspection in all stages of manufacture.

- The manufacturer's liability is void in the case of any damage caused by using the product contrary to its 

intended use, non-compliance with this operating manual, unauthorised modifications to the MISG-IO or 
assignment of insufficiently qualified skilled personnel.

U+: 

Positive supply connection

U-: 

Negative supply connection

C/Q: 

IO-Link

1    General

Strain Gauge Amplifier IO-Link

Page-3

1.1    Information

1.2    Signs and Abbreviations

Warning!

Noncompliance can cause injuries to persons and/or the demolition of the device.
There can be a danger to life.

Attention!

Noncompliance can cause faulty device operation or lead to property damage.

Information!

Noncompliance can influence the operation of the device or cause unintentional reactions. 

Danger!

Failure to comply with the safety instructions risks serious or fatal injury caused by electrical power.

Warning!

Possible dangerous situations caused by hot surfaces or liquids, which can lead to burns. Please 
avoid hot surfaces and liquids. .

Warning

Danger

Warning

For long-term storage, please avoid the following influences:

- Direct sunlight or proximity to hot objects
- Mechanical vibration, mechanical shock (rough mounting)
- Soot, steam, dust and corrosive gases

If possible, store the device inside its original packaging or equivalent

Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during 
transport (e.g. change in installation site, returns).

Check the device for any damage that may have been caused during transportation. Report obvious damage at once.

2.1    Transport

2.2    Packaging

2.3    Storage

2    Transport, Packaging, Storage

Summary of Contents for MISG-IO

Page 1: ...MISG IO MISG IO M MISG IO Operating Manual Strain Gauge Amplifier IO Link Page 1 Strain Gauge Amplifier IO Link MISG IO Strain Gauge IO Link ...

Page 2: ...eration 5 4 1 Function 5 4 2 Before Mounting 5 4 3 Product Label 5 4 4 Mounting 5 4 5 Electrical Start Up 5 4 6 Supply Voltage 6 4 7 Electrical Connection 6 4 8 Function Test Fault Detection 6 5 Fault Recovery 7 6 Maintenance Dismounting Return Cleaning Disposal 8 7 Technical Data 9 8 Dimensions 10 Strain Gauge Amplifier IO Link Page 2 ...

Page 3: ...U Positive supply connection U Negative supply connection C Q IO Link 1 General Strain Gauge Amplifier IO Link Page 3 1 1 Information 1 2 Signs and Abbreviations Warning Noncompliance can cause injuries to persons and or the demolition of the device There can be a danger to life Attention Noncompliance can cause faulty device operation or lead to property damage Information Noncompliance can influ...

Page 4: ...arry out the work described and recognize potential hazards independently Depending on the operating conditions other knowledge may also be required e g of corrosive media Risk of injury if qualification is insufficient Improper handling can lead to considerable property damage and injury The required tasks as described in this operating manual should only be conducted by qualified personnel with ...

Page 5: ...onal to the force change and is transmitted by the IO Link interface as a digital signal 4 Start Up Operation Strain Gauge Amplifier IO Link Page 5 4 1 Function 4 2 Before Mounting 4 3 Product Label Example Art Nr Part number SN Serial number 4 4 Mounting Check the delivery for completeness and visible defects immediately after receipt If parts are missing or if you detect visible defects inform t...

Page 6: ...onnection The listed information can occasionally deviate from the actual device values If this is the case please comply with the product label The product label always lists the current information for the specific device t The output signal must be proportional to the sensor signal If this is not the case it can be a sign of a wrong mounting position or a bad adjustment Please read under chapte...

Page 7: ...nsor shield cable area e g frequency converter remove interference source Operating temperatures too high low Comply with specified temperatures as per operating manual No connection to IO Link interface Cable break Check cables IO Link interface defect Replace IO Link interface 5 Fault Recovery Note Unjustified reclamations can incur additional costs Check for correct operation after each system ...

Page 8: ...sensor and IO Link interface connected to the MISG IO too have to be switched off and at dead voltage condition Only clean the device with a soft damp piece of cloth 6 4 Cleaning Warning The MISG IO measuring amplifiers are maintenance free Only the manufacturer is allowed to conduct repairs Before returning a device see chapter 6 4 To return a device use original packaging or similar To protect a...

Page 9: ...evel 0 24V as per IO Link specification Performance Parameters Measuring amplifier Accuracy max 0 05 of range sensor error Resolution Strain gauge channel 16 bit Filter setting strain gauge 0 5 s Switch on delay 5 s Response time 20 ms Supply Voltage 24 VDC Current Standard 30 mA Switching SIO max 100 mA Total current max 130 mA Reverse voltage protection Yes no function no damage Environmental Co...

Page 10: ...MISG IO M 28 24 72 95 35 Strain Gauge Amplifier IO Link Page 10 8 Dimensions in mm top view side view front view ...

Page 11: ...MISG IO M Strain Gauge Amplifier IO Link Page 11 ...

Page 12: ...MISG IO M Strain Gauge Amplifier IO Link Page 12 Subject to change version 44 175 ...

Reviews: