5

Programming Unit

300 SERIES COLD CLIMATE FLUSHING SYSTEM

Idle Mode – Waking Up

Normally the NODE display shows 
time and day, day of week, and 
battery life indicator. During a short 
period of inactivity the display will 
shut off to retain battery power 
Pressing any key will wake up the 
NODE to the Idle Mode.

Run Mode

When controller is operating a 
program, items shown on display 
will include station number (always 
“1”), program letter (A, B, or C), 
remaining runtime, and a blinking 
Rotor icon.

Programming

The NODE has the capability to 
hold 3 programs (A, B, C) and 4 
start times per program. When 
programming, flashing portion 
of display can be changed by 
pressing 

+

 or 

 keys. To change 

something not flashing, press 

LEFT

 or 

RIGHT ARROWS

 until 

desired item is flashing.

300 SERIES COLD CLIMATE 

BUILT-IN: (INTEGRATED)

NODE Programming Instructions
Batteries

The NODE uses standard 9-volt 
alkaline batteries to operate the 
control valve and program the 
controller. The controller can operate 
with one or two batteries installed. 
Under normal conditions, expected 
life is 1 year for a single battery and 
two years when using two.

 

Battery Installation
1. 

Unscrew rear body of the 

NODE to gain access to 
battery compartment.

2. 

Insert battery/batteries into 

battery tray and connect the 
battery connector to controller.

3. 

Make sure no water is inside 

battery compartment.

4. 

Screw the NODE rear body back 

onto front half.

NOTE: Make sure that seal marker 
on rear half of the NODE lines up 
with front half, ensuring a proper 
seal is created. Also, The NODE has 
non-volatile memory, which allows 
battery replacement without losing 
program information.

Setting Date/Time
1. 

Press

 RETURN/ENTER

 key until

 

CLOCK

 icon is displayed.

2. 

All 4 digits will be displayed 

representing the year. Use

 +

 

or

 – 

keys to change year. Press

 

RIGHT ARROW

 key to proceed to 

setting month.

3.  

All 4 digits will be displayed 

with two digits on left flashing 
representing the 

MONTH. 

Use

 + 

or

 – 

key to change month. Press

 

RIGHT ARROW 

key to proceed to 

setting 

DAY

.

4. 

Only two digits on right will be 

flashing, representing the 

DAY

.

 

Press

 + 

or

 – 

key to change day. 

Press 

RIGHT ARROW

 key to 

proceed to changing 

TIME

.

5. 

The 

AM/PM/24 

time setting is 

shown flashing. Press

 + 

or

 – 

key

 

to change to AM, PM, or 24-hour 
time. Press

 RIGHT ARROW

 key 

to proceed to setting the 

HOUR

.

6. 

All 4 numbers are shown with 

two numbers on the left flashing, 
representing the 

HOUR

. Press

 

or

 – 

key to change the hour. 

Press

 RIGHT ARROW

 key to 

proceed to setting 

MINUTES

.

7. 

All 4 numbers are shown with 

two numbers on right flashing, 
representing 

MINUTES

. Press

 

or

 – 

key to change minutes. 

(Pressing

 RIGHT ARROW

 key will 

return to YEAR setting at step 
#2.)

8. 

Press 

RETURN/ENTER 

key to 

proceed to next programming 
function, or allow controller to 
return to idle mode. 

Summary of Contents for HYDRO-GUARD 300 Series

Page 1: ...red by Mueller Co only and may not be applicable for any other use 2 DO NOT exceed the pressure ratings of any components or equipment Exceeding the rated pressure may result in serious injury and or property damage 3 Safety goggles and other appropriate protective gear should be used Failure to do so could result in serious injury 300 Series Cold Climate Flushing System Installation Instructions ...

Page 2: ...point of discharge i e a storm sewer swale storm pond etc The meter and flushing assembly can be raised for maintenance and repair and then lowered back down into the box below the frost line A medium density foam insulation pad freeze protection system and composite lid an optional cast lid is available help protect the flushing and meter assembly from freezing in the winter WARNING Proper liftin...

Page 3: ...sting grade and ensure the meter lid is level with existing grade 7 Place the pit in the excavated area and connect the inlet piping Hand tighten the fitting to the pit then turn two full turns with a wrench This will result in a leak tight connection without placing undue stress on the pit piping 300 SERIES COLD CLIMATE REQUIRES CONTROLLER Buetooth Programming Instructions The BL KR battery power...

Page 4: ...pulate the device list can be found on the label located on the back of the controller housing with the designation Default name The App will indicate that it is in the process of connecting 8 Once the device is connected it will appear on the home screen when you launch the Application Application Home Screen Device Home Screen To add another controller tap the plus sign in the upper right hand c...

Page 5: ... connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losing program information Setting Date Time 1 Press RETURN ENTER key until CLOCK...

Page 6: ...tart time in 15 minute increments 4 Press RIGHT ARROW key to add an additional START TIME to program displayed The start time number is shown in upper left corner of display 5 Press PRG key to add START TIME to a different program 6 Press RETURN ENTER key to proceed to next programming function or allow controller to return to idle mode Setting Flush Duration Times 1 Press RETURN ENTER key until H...

Page 7: ...tirety in order to allow for required service and maintenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit Disassembly 1 Shut off water supply to the unit and remove the green housing cover 2 Remove the composite or cast iron lid of 300 Series Cold Climate protective ground sleeve 3 Remove foam insulation pad 4 Using the lifti...

Page 8: ...eaks or lack of connection Run a manual flush and confirm the solenoid plunger is kicking out and pulling back in by listening for a click Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures PROBLEM CAUSE SOLUTION Controller does not flush as desired ...

Page 9: ...wo 9 volt alkaline batteries Tighten the cap completely to ensure a water tight fit The following is a brief overview and introduction to our options Integrated Sample Station The 300 Series Cold Climate Sub Surface Discharge Unit features a Sample Port quick connect that allows the end user to collect a sample from the 300 Series Cold Climate installation site To collect a sample from the sample ...

Page 10: ...INE DECHLOR 3 HG 11010 1 HITVLVE 510 000 WITHOUT STEM 4 780029 2150 300 Series Cold 48 IN SHELL SUB ASSEMBLY 5 300Series BL BlueTooth Controller Programming Option 6 546784 HG8 CC 300 Series Cold CC PLATFORM ASSEMBLY 7 790119 21 IN INSULATING PAD 8 780034 1848 HG8 300 Series Cold Coil Sub Assembly 9 HG 2321 21IN STEEL PLATFORM HC 21 25A 1 2 3 7 4 5 6 8 9 ...

Page 11: ...11 Notes 300 SERIES COLD CLIMATE FLUSHING SYSTEM ...

Page 12: ... are liable only for their own acts and omissions and not those of each other MWP brands include Mueller Echologics Hydro Gate Hydro Guard HYMAX Jones Krausz Mi Net Milliken Pratt Pratt Industrial Singer and U S Pipe Valve Hydrant Please see muellerwp com brands and krauszusa com to learn more 2021 Mueller Water Products Inc All Rights Reserved The trademarks logos and service marks displayed in t...

Reviews: