Muller HYDRO-GUARD 300 Series Operating Instructions Manual Download Page 4

4

Programming Unit

300 SERIES COLD CLIMATE FLUSHING SYSTEM

5.  The app will now ask what type 

of Bluetooth device you would 
like to add:

NOTE: The BL-KR V1.0 and BL-KR 
V2.0 have identical hardware and 
software configurations. The only 
distinction is the outside plastic 
housing.

6.  The App will now search for 

devices in range.

7.  Choose the Controller. 

The 

serial numbers that populate 
the device list can be found on 
the label located on the back of 
the controller housing with the 
designation “Default name.” The 
App will indicate that it is in the 
process of connecting.

8.  Once the device is connected, it 

will appear on the home screen 
when you launch the Application.

Application Home Screen:

Device Home Screen:

To add another controller, 
tap the plus sign in the 
upper right hand corner 
of the home screen. 

NOTE: You can associate up to 400 devices with the K-Rain BL-KR App. The number of devices is limited to the 
internal memory on the Smartphone/Tablet.  

Summary of Contents for HYDRO-GUARD 300 Series

Page 1: ...red by Mueller Co only and may not be applicable for any other use 2 DO NOT exceed the pressure ratings of any components or equipment Exceeding the rated pressure may result in serious injury and or property damage 3 Safety goggles and other appropriate protective gear should be used Failure to do so could result in serious injury 300 Series Cold Climate Flushing System Installation Instructions ...

Page 2: ...point of discharge i e a storm sewer swale storm pond etc The meter and flushing assembly can be raised for maintenance and repair and then lowered back down into the box below the frost line A medium density foam insulation pad freeze protection system and composite lid an optional cast lid is available help protect the flushing and meter assembly from freezing in the winter WARNING Proper liftin...

Page 3: ...sting grade and ensure the meter lid is level with existing grade 7 Place the pit in the excavated area and connect the inlet piping Hand tighten the fitting to the pit then turn two full turns with a wrench This will result in a leak tight connection without placing undue stress on the pit piping 300 SERIES COLD CLIMATE REQUIRES CONTROLLER Buetooth Programming Instructions The BL KR battery power...

Page 4: ...pulate the device list can be found on the label located on the back of the controller housing with the designation Default name The App will indicate that it is in the process of connecting 8 Once the device is connected it will appear on the home screen when you launch the Application Application Home Screen Device Home Screen To add another controller tap the plus sign in the upper right hand c...

Page 5: ... connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losing program information Setting Date Time 1 Press RETURN ENTER key until CLOCK...

Page 6: ...tart time in 15 minute increments 4 Press RIGHT ARROW key to add an additional START TIME to program displayed The start time number is shown in upper left corner of display 5 Press PRG key to add START TIME to a different program 6 Press RETURN ENTER key to proceed to next programming function or allow controller to return to idle mode Setting Flush Duration Times 1 Press RETURN ENTER key until H...

Page 7: ...tirety in order to allow for required service and maintenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit Disassembly 1 Shut off water supply to the unit and remove the green housing cover 2 Remove the composite or cast iron lid of 300 Series Cold Climate protective ground sleeve 3 Remove foam insulation pad 4 Using the lifti...

Page 8: ...eaks or lack of connection Run a manual flush and confirm the solenoid plunger is kicking out and pulling back in by listening for a click Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures PROBLEM CAUSE SOLUTION Controller does not flush as desired ...

Page 9: ...wo 9 volt alkaline batteries Tighten the cap completely to ensure a water tight fit The following is a brief overview and introduction to our options Integrated Sample Station The 300 Series Cold Climate Sub Surface Discharge Unit features a Sample Port quick connect that allows the end user to collect a sample from the 300 Series Cold Climate installation site To collect a sample from the sample ...

Page 10: ...INE DECHLOR 3 HG 11010 1 HITVLVE 510 000 WITHOUT STEM 4 780029 2150 300 Series Cold 48 IN SHELL SUB ASSEMBLY 5 300Series BL BlueTooth Controller Programming Option 6 546784 HG8 CC 300 Series Cold CC PLATFORM ASSEMBLY 7 790119 21 IN INSULATING PAD 8 780034 1848 HG8 300 Series Cold Coil Sub Assembly 9 HG 2321 21IN STEEL PLATFORM HC 21 25A 1 2 3 7 4 5 6 8 9 ...

Page 11: ...11 Notes 300 SERIES COLD CLIMATE FLUSHING SYSTEM ...

Page 12: ... are liable only for their own acts and omissions and not those of each other MWP brands include Mueller Echologics Hydro Gate Hydro Guard HYMAX Jones Krausz Mi Net Milliken Pratt Pratt Industrial Singer and U S Pipe Valve Hydrant Please see muellerwp com brands and krauszusa com to learn more 2021 Mueller Water Products Inc All Rights Reserved The trademarks logos and service marks displayed in t...