ISOBUS-TC task processing
Configuring the list of connections
10
31302713-02-US
V9.20191001
67
“Simplified target rate assignment?” parameter
Optional parameter. Set to “No” per default.
When you activate this parameter, the target rate settings from the previous task can be adopted for
a new task. To do so, you must set the parameter to “Yes”.
When you then create a new task, the following message appears:
“Should be target rate settings for the implement be adopted from the previous task?”
Confirm this message to adopt the target rate settings.
Configuring the list of connections
The list of connections indicates the ISOBUS job computers from which the display will load the
geometries of the connected devices. This geometry is required in order to calculate the position of all
implement components on the basis of the GPS signal. Only in this way are precise parallel driving
and section switching possible.
Icon for the tractor
ISO name of the tractor
Connection between the tractor and the job
computer is established
- Connected implements
Name of the job computer
Icon for the ISOBUS job computer
Not all of the equipment in the list must be
connected.
- Disconnected implements
In simple systems, the display can set up the list of connections automatically. In particular, when the
ME display is the only unit containing the tractor geometry.
It can however still be necessary to set the list of connection manually in the following instances:
▪
If a tractor job computer (Tractor-ECU), in which the tractor geometry is saved, is mounted as an
independent job computer on the tractor. In this instance, you must decide which Tractor-ECU is
connected in the list of connections with other equipment: the application on the ME display or
on the tractor job computer.
▪
If the system cannot organize the ISOBUS job computer by itself. For example when more than
one implement is connected to the tractor (e.g.: slurry tanker and planter/seeder).
▪
When the connection to an ISOBUS job computer is interrupted during the start-up of a ISO-XML
task. In most cases, the list of connections will be set correctly as soon as you reconnect the
ISOBUS job computer.
▪
If this error message appears when starting the display: "List of connection is incomplete."