MOUNTING
Note: LED FLEX II and LED FLEX II RGB share the same track, channel and end caps.
1. Make mounting clips using cut pieces of track or order clips (P2-NF-CLIPS, 10 per pack, sold separately) for curves and Shapes on a flat
mounting surface; or for straight line applications, use P2-NF-TRACK-3 (3ft length, sold separately) mounting tracks; P2-NF-CHAN-3 (3ft
aluminum channel) is also available (sold separately).
2. Make sure that the distance between any two parallel runs of lighting is at least 1/2” apart.
3. Gently press flexible light into track, channel and/or clips so that it snaps into place.
Page 4 of 4
FIGURE 6
TO REPLACE FUSE (SEE FIGURE 6):
This plug contains an electrical fuse as a safety feature.
1. Disconnect power before replacing the fuse.
2. Grasp plug and remove from the receptacle or other outlet device.
3. Do not unplug by pulling on the cord.
4. Slide open the fuse access cover (See figure 6).
5. Remove old fuse carefully.
6. Never attempt to replace the fuse with a higher wattage fuse. Use
only 8Amp 125Volt fuse. Failure to do so may be a fire hazard. (One
spare fuse is included; stored inside plug for convenience)
7. Set new fuse in holder and close fuse access cover.
Fuse is inside plug.
Slide open fuse access cover as shown.
120V
INSTALLATION INSTRUCTIONS
P2-NF Series
DO NOT TWIST, HANG VERTICALLY, SUSPEND UNSUPPORTED IN THE MIDDLE, BEND UPWARDS (ARCH) OR DOWNWARDS (DIP).
MINIMUM BEND RADIUS FOR SIDE-TO-SIDE BENDS IS SHOWN BELOW.
×
×
×
×
MINIMUM BEND
RADIUS = 50mm
×
©2019 LEDalux® www.LEDalux.com
46 Baker Street, Providence, RI 02905 Phone: (800) 556-7690 Fax: (401) 941-2929
LED FLEX II, BULK REELS