STEP 1
Using 6” concrete blocks, build enclosure walls
around the oven at the perimeter of the concrete
slab to a minimum height of 35”.
STEP 2
Setting Anchor Bolts: Before the grout sets on the top
coarse of concrete blocks, place
½
” x 10” foundation
bolts for the roof framing.
STEP 3
Once the oven enclosure walls have been completed
and before the top is put in place, fill this enclosure
with the specified loose Perlite 9” on top (measured
from the 1” Thermal Insulation Blanket).
STEP 4
Place pressure treated 2” x 4” (P.H.T.F’s) or metal
studs around the top edge of the concrete blocks
and attach to the foundation bolts. Build your roof
rafters to the appropriate pitch for the roofing
materials being used and attach
½
” plywood.
Place a 2” diameter metal weatherproof air vent
on the back near the top of your structure. You
may use nonflammable roofing materials of your
choice. (e.g. Slate, Roof Tiles, Metal etc.)
GABLE SHAPED ENCLOSURE
Example