2.3
Use new DLL with older software
The DLL 'Jmlaser.dll' which acts a bridge between your application software and the hardware
driver, was designed to be compatible with older software.
If you use a software which uses the old 'EasyLase.dll', the use of the new dll normally would not be
possible.
But the new Jmlaser.dll contains all functions to control also older devices.
The new DLL contains all functions (calls) of
•
EasyLase USB old version
•
NetLase
•
EasyLase USB II
•
EasyLase USB LC
•
Phoenix Live Interface
If you use a software which uses the old EasyLase device, just rename the new DLL Jmlaser.dll to
'Easylase.dll' and replace the old file 'Easylase.dll' with this file.
Your software now will support the old EasyLase hardware as well as the new EasyLase II. (and
also all other devices listed above).
Note:
If your software does not work with a specific product, the reason can be that the manufacturer of
this software excludes the use of a specific hardware.
The new DLL contains various license functions.
For example, the software 'LDS Nano' will not accept any other hardware except 'EasyLase LC'.
Special Note for Software Mamba:
Mamba does not need a specific name of the DLL.
So you can use the file 'Jmlaser.mld' coming with the CD of EasyLase II (or rename 'Jmlaser.dll' to
'Jmlaser.mld').
Note that all older device-DLLs, like 'EasyLase.mld' or 'NetLase.mld' have to be removed from the
Mamba directory. Otherwise a collision between new and old device-dlls will happen.