6
Stop
START
STOP
Main Power
Switch
START
STOP
Main Power
Switch
START
STOP
Main Power
Switch
1
Carefully turn the blue pressure
valve
counter-clockwise
until
the pressure reads 0 bar.
2
Drain the system fully by
opening the drain valve,
situated at the bottom of
the BlueBox unit, next to the
electrical cabinet.
Run the BlueBox for 1 minute
without pressure and without
feed water intake.
3
Stop the pump by pressing the
red Stop button.
Close the drain valve.
4
Turn the black switch counter-
clockwise to turn off the
BlueBox.
WARNING!
Never stop the BlueBox
with pressure on.
PART 3 AFTER USING BLUEBOX
(electrical version)
0 bars
ill. 12
ill. 13
ill. 14
Off
Electrical cabinet
Electrical cabinet
Drain
valve
ill. 15