Lamp timer display
Counts down from 365 days to show time for annual lamp replacement.
Lamp timer reset
After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365.
Alarm
Press to silence audible alarm.
When the alarm is due to the lamp’s age, the mute button will silence the audible alarm for 7 days; this
may be repeated up to a maximum of 4 times. After that, the button will silence for only 24 hours.
When the alarm is due to any other issue, the mute button will silence the audible alarm for 24 hours.
Display
SLEEVE CLEANING & LAMP REPLACEMENT
Lamp replacement
Unplug the BlueBox from the electrical socket.
Let the unit cool for 10 minutes.
Remove the UV-lamp from the container.
Sleeve cleaning
Minerals in the water slowly form a coating on the sleeve. This coating must be removed because
it reduces the amount of UV light reaching the water, thereby reducing purification performance.
Equipment required
Clean cotton
Latex or plastic gloves are preferred
Scale remover
Vinegar or a citrus-based product
Cloth
Must be soft, lint-free, and chemical-free. No clean-wipes must be used
Cotton swab
Lamp life
The amount of UV light created by the lamp decreases over time, requiring a replacement of the
lamp every 12 months. The controller displays the total lamp life remaining in days.
At 0 (zero) days, the controller will display ‘A3’ and supply an intermittent audible chirp (1 second
on, 5 seconds off), indicating the need to change the lamp.
NOTE
The UV system is designed to operate continuously and should not be shut
off for short periods of time, such as over a period of less than three weeks.
RESETTING LAMP LIFE
1
Disconnect the lamp from the controller.
2
Hold the ‘RESET’ button down while reapplying power to the Controller until you see ‘rSet’
on the display, then release.
3
A 5 second delay will occur until your hear an audible tone and the display will once again
read ‘365’.