background image

11

Lamp timer display

Counts down from 365 days to show time for annual lamp replacement.

Lamp timer reset

After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365.

Alarm

Press to silence audible alarm. 
When the alarm is due to the lamp’s age, the mute button will silence the audible alarm for 7 days; this 
may be repeated up to a maximum of 4 times. After that, the button will silence for only 24 hours.
When the alarm is due to any other issue, the mute button will silence the audible alarm for 24 hours.

Display

SLEEVE CLEANING & LAMP REPLACEMENT

Lamp replacement

Unplug the BlueBox from the electrical socket.
Let the unit cool for 10 minutes.
Remove the UV-lamp from the container.

Sleeve cleaning

Minerals in the water slowly form a coating on the sleeve. This coating must be removed because 
it reduces the amount of UV light reaching the water, thereby reducing purification performance.

Equipment required

Clean cotton 

Latex or plastic gloves are preferred

Scale remover 

Vinegar or a citrus-based product 

Cloth 

Must be soft, lint-free, and chemical-free. No clean-wipes must be used

Cotton swab 

Lamp life

The amount of UV light created by the lamp decreases over time, requiring a replacement of the 
lamp every 12 months. The controller displays the total lamp life remaining in days.
At 0 (zero) days, the controller will display ‘A3’ and supply an intermittent audible chirp (1 second 
on, 5 seconds off), indicating the need to change the lamp.

NOTE
The UV system is designed to operate continuously and should not be shut
off for short periods of time, such as over a period of less than three weeks.

RESETTING LAMP LIFE

1

  Disconnect the lamp from the controller.

2

  Hold the ‘RESET’ button down while reapplying power to the Controller until you see ‘rSet’ 

on the display, then release.

3

  A 5 second delay will occur until your hear an audible tone and the display will once again 

read ‘365’.

Summary of Contents for BlueBox 1200 RORS

Page 1: ...PURE WATER ANYTIME ANYWHERE BlueBox 1200 RORS Operating manual...

Page 2: ...2 PURE WATER ANYTIME ANYWHERE BlueBox 1200 RORS Post chlorination and UV disinfection features...

Page 3: ...blue and black hoses onto the quick couplings Follow the colour codes Red sign red hose Blue sign blue hose Black sign black hose 3 Prepare the floating device The floating position can be adjusted wi...

Page 4: ...r supply 2 Before starting the pump the blue pressure valve must be opened by turning it all the way counter clockwise IMPORTANT The BlueBox must not be started with pressure on 3 Turn the black power...

Page 5: ...light must be changed after 365 days of operation Please see maintenance section 8 Non potable not suitable for drinking water will come out of the red hose Flush water outlet Drinking water can be t...

Page 6: ...bottom of the BlueBox unit next to the electrical cabinet Run the BlueBox for 1 minute without pressure and without feed water intake 3 Stop the pump by pressing the red Stop button Close the drain va...

Page 7: ...e filter from the housing and rinse both with clean water IMPORTANT The filters must NOT be wrought or squeezed 3 Reinstall the used or new filter cartridges in the housings and mount back onto the co...

Page 8: ...age pipes in the container are not blocked Check all hoses for holes tears and other signs of damage and water leakage Check the pump s membrane If there is water leaking out of the small hole at the...

Page 9: ...01 in 50 litres of water Insert all three hoses into the container with the cleaning fluid Flush water outlet Raw water inlet and Clean water 6 Start the BlueBox and let the system rinse without press...

Page 10: ...r breaker tripped Transient voltage surge suppressor TVSS damaged Power supply damaged Reset GFCI and or breaker Replace TVSS Replace power supply and use a TVSS GFCI or breaker repeatedly trips Conne...

Page 11: ...ght reaching the water thereby reducing purification performance Equipment required Clean cotton Latex or plastic gloves are preferred Scale remover Vinegar or a citrus based product Cloth Must be sof...

Page 12: ...1 2 x 1 2 Modul_RO1200 Complete RO membrane setup on frame UV disinfection system 14201 9105 UV light bulb 14201 9205 UV quartz tube Pump parts 750153 Hardi pump 603 7 membrane kit 210022 Bearings typ...

Page 13: ...n Power Switch 365 Suction chamber 703032 Membrane kit of four filters 750153 Bearings 6205 210022 6007 60207 Flush water outlet Red hose DH10008 Raw water inlet Black hose DH10009 Clean water outlet...

Page 14: ...with brush see ill on page 7 Dismantle black absorption hose and fill with water Take apart contra vent and clean inside Pump is dismantled by loosing the bolts membranes are loosened and changed see...

Page 15: ...essure for a while in order to defrost the membranes without damaging them For long term storage in freezing temperatures please contact Much More Water at info muchmorewater com As an industrial stan...

Page 16: ...PURE WATER ANYTIME ANYWHERE Much More Water A S Staerkendevej 43 DK 4000 Roskilde phone 45 8020 8020 info MuchMoreWater com www MuchMoreWater com July 2017...