PURE WATER –

 

ANYTIME

 –

 ANYWHERE

BlueBox 1200 RORS

Operating manual

Summary of Contents for BlueBox 1200 RORS

Page 1: ...PURE WATER ANYTIME ANYWHERE BlueBox 1200 RORS Operating manual...

Page 2: ...2 PURE WATER ANYTIME ANYWHERE BlueBox 1200 RORS Post chlorination and UV disinfection features...

Page 3: ...blue and black hoses onto the quick couplings Follow the colour codes Red sign red hose Blue sign blue hose Black sign black hose 3 Prepare the floating device The floating position can be adjusted wi...

Page 4: ...r supply 2 Before starting the pump the blue pressure valve must be opened by turning it all the way counter clockwise IMPORTANT The BlueBox must not be started with pressure on 3 Turn the black power...

Page 5: ...light must be changed after 365 days of operation Please see maintenance section 8 Non potable not suitable for drinking water will come out of the red hose Flush water outlet Drinking water can be t...

Page 6: ...bottom of the BlueBox unit next to the electrical cabinet Run the BlueBox for 1 minute without pressure and without feed water intake 3 Stop the pump by pressing the red Stop button Close the drain va...

Page 7: ...e filter from the housing and rinse both with clean water IMPORTANT The filters must NOT be wrought or squeezed 3 Reinstall the used or new filter cartridges in the housings and mount back onto the co...

Page 8: ...age pipes in the container are not blocked Check all hoses for holes tears and other signs of damage and water leakage Check the pump s membrane If there is water leaking out of the small hole at the...

Page 9: ...01 in 50 litres of water Insert all three hoses into the container with the cleaning fluid Flush water outlet Raw water inlet and Clean water 6 Start the BlueBox and let the system rinse without press...

Page 10: ...r breaker tripped Transient voltage surge suppressor TVSS damaged Power supply damaged Reset GFCI and or breaker Replace TVSS Replace power supply and use a TVSS GFCI or breaker repeatedly trips Conne...

Page 11: ...ght reaching the water thereby reducing purification performance Equipment required Clean cotton Latex or plastic gloves are preferred Scale remover Vinegar or a citrus based product Cloth Must be sof...

Page 12: ...1 2 x 1 2 Modul_RO1200 Complete RO membrane setup on frame UV disinfection system 14201 9105 UV light bulb 14201 9205 UV quartz tube Pump parts 750153 Hardi pump 603 7 membrane kit 210022 Bearings typ...

Page 13: ...n Power Switch 365 Suction chamber 703032 Membrane kit of four filters 750153 Bearings 6205 210022 6007 60207 Flush water outlet Red hose DH10008 Raw water inlet Black hose DH10009 Clean water outlet...

Page 14: ...with brush see ill on page 7 Dismantle black absorption hose and fill with water Take apart contra vent and clean inside Pump is dismantled by loosing the bolts membranes are loosened and changed see...

Page 15: ...essure for a while in order to defrost the membranes without damaging them For long term storage in freezing temperatures please contact Much More Water at info muchmorewater com As an industrial stan...