4.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 182);
Preheat engine oil if required.
Coolant circuit
Check coolant level (→ Page 225).
Coolant circuit
Heat coolant with coolant preheating unit.
Engine control system
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 72).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 72).
ECU
Check plug connections (→ Page 251).
EIM
Check plug connections (→ Page 250).
EMU 8
Check plug connections (→ Page 249).
74 | Operation | MS150048/05E 2018-03
TIM-ID: 0000010656 - 004