4.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 144);
Preheat engine oil if required.
Coolant circuit
Check coolant level (→ Page 156).
Coolant circuit
Heat coolant with coolant preheating unit.
Engine control system
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 55).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 55).
ECU
Check plug connections (→ Page 181).
EIM
Check plug connections (→ Page 180).
EMU 8
Check plug connections (→ Page 179).
MS150048/04E 2013-07 | Operation | 57
TIM-ID: 0000010656 - 004