7.3.2 Valve clearance – Check and adjustment
Preconditions
☑
Engine shut down and starting disabled.
☑
Engine coolant temperature is max. 40 °C.
☑
Valves are closed.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Feeler gauge
Y20098771
1
Torque wrench, 60-320 Nm
F30452768
1
Box wrench socket, 24 mm
F30039526
1
Engine oil
Preparatory steps
1.
Remove cylinder head cover (→ Page 120).
2.
Install barring device (→ Page 109).
3.
The OT (TDC) marking (1) (if fitted) on the
flywheel must not be used for reference.
116 | Task Description | MS150048/04E 2013-07
TIM-ID: 0000000922 - 010