8.21.4 Engine Monitoring Unit EMU 7 – Plug connection check
Preconditions
☑
Engine is stopped and starting disabled.
Checking EMU plug connections
1.
Check both connectors on EMU (2) for firm
seating. Ensure that the clips (1) are engag-
ed.
2.
Check screws (3) of cable clamps on EMU (2)
for firm seating. Ensure that cable clamps are
not faulty.
MS150061/06E 2016-02
| Accessories for (Electronic) Engine Governor / Control System | 131
TIM-ID: 0000035355 - 002