1.5 Safety regulations for maintenance and repair work
Safety regulations prior to maintenance and repair work
Have maintenance or repair work carried out by qualified and authorized personnel only.
Allow the product to cool down to less than 50°C before starting maintenance work (risk of explosion
of oil vapors, fluids and lubricants, risk of burning).
Before starting work, relieve pressure in systems and compressed-air lines which are to be opened. Use
suitable containers of adequate capacity to catch fluids and lubricants.
When changing the oil or working on the fuel system, ensure that the service room is adequately venti-
lated.
Never carry out maintenance and repair work with the product in operation.
Carry out functional checks on products which are in operation in accordance with the instructions only
when expressly permitted to do so.
Carry out functional checks only when the product is running in the low load range and only for as long
as absolutely necessary.
Secure the product against unintentional starting, e.g. with start interlock.
Attach "Do not operate" sign in the operating area or to control equipment.
Disconnect the battery. Lock contactors.
Close the main valve on the compressed-air system and vent the compressed-air line when pneumatic
starters are fitted.
Disconnect the control equipment from the product.
The following applies to starters with copper-beryllium alloy pinions:
• Wear breathing protection of filter class P3 during maintenance work. Do not blow out the interior of
the flywheel housing or the starter with compressed air. Clean the flywheel housing inside with a
class H dust extraction device.
• Observe the safety data sheet.
Safety regulations during maintenance and repair work
Take special care when removing ventilation or plug screws from the product. Cover the screw or plug
with a rag to prevent fluids escaping under pressure.
Take care when draining hot fluids and lubricants (risk of burning).
Use only proper and calibrated tools. Observe the specified tightening torques during assembly or dis-
assembly.
Carry out work only on assemblies or plants which are properly secured.
Never use lines for climbing.
Keep fuel injection lines and connections clean.
Always seal connections with caps or covers if a line is removed or opened.
Take care not to damage lines, in particular fuel lines, during maintenance and repair work.
Ensure that all retainers and dampers are installed correctly.
Ensure that all fuel injection and pressurized oil lines are installed with enough clearance to prevent
contact with other components. Do not place fuel or oil lines near hot components.
Do not touch elastomeric seals if they have carbonized or resinous appearance unless hands are prop-
erly protected.
Note cooling time for components which are heated for installation or removal (risk of burning).
MS15018/02E 2013-09
| Safety | 9
TIM-ID: 0000040535 - 002