![MTU 10V2000Mx4 Operating Instructions Manual Download Page 35](http://html1.mh-extra.com/html/mtu/10v2000mx4/10v2000mx4_operating-instructions-manual_1852617035.webp)
Number of cylinders
8
Cylinder displacement
Liters
2.23
Total displacement
Liters
17.84
Number of inlet valves per cylinder
2
Number of exhaust valves per cylinder
2
Raw water circuit (open circuit)
Number of cylinders
8
Raw water pump: Inlet pressure, min.
L
bar
-0.4
Raw water pump: inlet pressure, max.
L
bar
+0.5
Pressure loss in engine-external raw water system, max.
L
bar
1.2
Lube oil system
Number of cylinders
8
Lube oil operating temperature before engine, from
R
°C
74
Lube-oil operating temperature before engine, to
R
°C
83
Lube oil operating pressure before engine, from
R
bar
9.0
Lube oil operating pressure before engine, to
R
bar
10.0
Lube oil operating pressure (low idle) (meas. point: before engine)
R
bar
2.5
Fuel system
Number of cylinders
8
Fuel pressure at engine inlet connection, min. (when engine is starting)
L
bar
-0.3
Fuel pressure at engine inlet connection, min. (during engine operation)
L
bar
-0.3
Fuel pressure at engine inlet connection, max. (when engine is starting)
L
bar
+0.25
Fuel supply flow, max.
A
liters/min
4.8
General operating data
Number of cylinders
8
Firing speed, from
R
rpm
100
Firing speed, to
R
rpm
120
Starter (electric)
Number of cylinders
8
Rated starter voltage (standard design)
R
V=
24
Inclinations - standard oil system (reference: waterline)
Number of cylinders
8
Longitudinal inclination, continuous max. driving end down (option: max. oper-
ating inclinations)
L
Degrees
(°)
15
Longitudinal inclination, temporary max. driving end down (option: max. oper-
ating inclinations)
L
Degrees
(°)
20
MS150060/04E 2016-02
| Technical Data | 35