355 – AL Open Load Cylinder B5
Cause
Corrective action
Disruption fault in injector wiring
of cylinder B5.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
356 – AL Open Load Cylinder B6
Cause
Corrective action
Disruption fault in injector wiring
of cylinder B6.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
381 – AL Wiring TOP 1
Cause
Corrective action
Short circuit or wire break on
transistor output 1, plant (TOP 1).
1. Check wiring (→ Page 135).
2. Contact Service.
382 – AL Wiring TOP 2
Cause
Corrective action
Short circuit or wire break on
transistor output 2, plant (TOP 2).
1. Check wiring (→ Page 135).
2. Contact Service.
383 – AL Wiring TOP 3
Cause
Corrective action
Short circuit or wire break on
transistor output 3, plant (TOP 3).
1. Check wiring (→ Page 135).
2. Contact Service.
384 – AL Wiring TOP 4
Cause
Corrective action
Short circuit or wire break on
transistor output 4, plant (TOP 4).
1. Check wiring (→ Page 135).
2. Contact Service.
410 – LO U-PDU
Cause
Corrective action
The ECU voltage to control the
injectors has violated limit value
1.
1. Check power supply (plant).
2. Check wiring (→ Page 135).
3. Contact Service.
411 – LOLO U-PDU
Cause
Corrective action
The ECU voltage to control the
injectors has violated limit value
2.
1. Check power supply (plant).
2. Check wiring (→ Page 135).
3. Contact Service.
76 | Troubleshooting | MS150100/04E 2015-09