Temposonics
®
MH-Series
Brief Instructions
I
3
I
Do not reprocess the sensor or cylinder afterwards.
The sensor might be damaged.
Do not step on the sensor.
The sensor might be damaged.
Forseeable misuse
Consequence
Wrong sensor connection
The sensor will not work
properly or will be destroyed
Operate the sensor out of the
operating temperature range
No signal output /
The sensor can be damaged
Power supply is out of the
defi ned range
Signal output is wrong /
no signal output /
the sensor will be damaged
Position measurement is
infl uenced by an external
magnetic fi eld
Signal output is wrong
Cylinder bore hole too small Component damage due to
excessive installation force
required.
Cylinder bore hole after
welding too small
Component damage due to
excessive installation force
required.
Sharp edges
Damage to cables and
conductors
Rough sensor handling
Destruction of internal
components
Welding after installation
High energy voltage peaks
or currents are fed to the
sensor, damaging housing or
electronic components.
Cables are damaged
Short circuit – the sensor can
be destroyed / sensor does
not respond
Loose connectors
Liquid can penetrate into the
sensor into the sensor hous-
ing through cables or strands
and cause short circuit or
corrosion of electronics
components
Spacers are missing or
installed in a wrong order
Error in position
measurement
Wrong connection
of ground / shield
Signal output is disturbed /
The electronics can be
damaged
Use of a magnet that is not
certifi ed by MTS Sensors
Error in position
measurement
2.2 Forseeable misuse
Manuals, Software & 3D models available at:
www.mtssensors.com