Page 1: ...MotionPlus EDC Encoder Digital Controller Getting Started Manual 2101 North Broadway 0901 New Ulm MN 56073 150604 00C Telephone 507 354 1616 MTS Systems Corporation 2000 Fax 507 354 1611...

Page 2: ...ual Part No 150655 00 is essential You can t install or program the EDC without it If it s missing call the number below The Getting Started Manual Part No 150604 00 Problems If your EDC package is in...

Page 3: ...arameters Servo command output connection Fault input connection Enable output connection Jogging the system and general check out A box is provided for each step By checking off each box you can be s...

Page 4: ...splay screen and general operation of the EDC Controller Connecting AC Power EDC User s Manual Chapter 2 Installation Section AC Power Connections Procedure Follow the instructions in the above sectio...

Page 5: ...Limits enables voltage other than 15 V Servo outputs if isolation is required or if maximum voltage between 10 V and 24 V is required Programmable I O if isolation is required if current greater than...

Page 6: ...in the Setup Access menu Limit Inputs Turns off Enable output and zeroes Servo command when connection is open to ground Connect the Interlock Access and Limit inputs Test for accurate connection of...

Page 7: ...bration Parameters EDC User s Manual Chapter 3 Setup Section Setting up Calibration Parameters Calibration parameters control the scale and movement of the actuator It is important that you be able to...

Page 8: ...00 Set excess error EX ERROR to an acceptable value this value depends on the scale value set earlier Set all other servo loop parameters to 0 Remove power from the Controller before proceeding Encode...

Page 9: ...ases component changes on the EDC If jumper or component changes are necessary remove power from the Controller before proceeding Then remove the Controller front cover as described in the EDC User s...

Page 10: ...e with the EDC Controller enable output The EDC Controller enable is factory configured as ON low To set it for ON high jumper changes are necessary Before changing jumpers or making connections make...

Page 11: ...2 Installation Servo Output Connections Swap the Command connection with the Command connection Press the Mode key until the top line of the display reads RUN MODE then follow the directions in the ab...