Move the magnet to the desired mechanical start position and calibrate the offset as
follows:
1) Hold the programming switch in Position #2 until the 'ZERO' LED begins to flash (
≈
3 sec.)
ADJUST
The displacement output indicated position without the offset calculation
2) Enter the desired offset value using BCD switches S1-S6.
EXAMPLE: Switch Settings S1-S6 for Offset Value
1) Hold the programming switch in Position #2 to restart programming sequence. (
≈
3 sec.)
SET UP
NOTE:
If a set value is overwritten, the programming mode
has to be set again by repeatedly tapping the dip
switch to Position #1.
OFFSET
NEGATIVE OFFSET (in inches)
BCD Switch
-00.3571
-04.5841
-03.5705
-45.8405
S1
1
1
5
5
S2
7
4
0
0
S3
5
8
7
4
S4
3
5
5
8
S5
0
4
3
5
S6
5
5
5
9
POSITIVE OFFSET (in inches)
BCD Switch
+00.3571
+04.5841
+03.5705
+45.8405
S1
1
1
5
5
S2
7
4
0
0
S3
5
8
7
4
S4
3
5
5
8
S5
0
4
3
5
S6
0
0
0
4
OFFSET
21
Summary of Contents for MK292
Page 4: ...4...