CHECK REGULARLY 

 

Clean  any  impurities  in  the  air-inlet  filter  regularly.  Otherwise  the  impurities  will 
reduce the efficiency or breakdown the pump. 

 

If  regular  checks  on  the  pump  are  neglected,  the  pernicious  fluid  will  invade  the 
stratochamber  of  the  pump  when  the  diaphragm  breaks,  and  the  pump  will 
breakdown. Even cause an accident to surrounding people. 

 

The diaphragm, ball valve, ball set and O-ring are all expendables. It is recommended 
to change them when the pump operates in stipulation number of times. 

 

The  life  expectancy  of  diaphragm  is  almost  ten  million  operations.  (This  is  just  an 
estimate. The life will cut down when the fluid has dust of metal, iron filings, wear-
resisting particles or other foreign matter). 

 

The O.D. of ball valve is shown below: 

o

 

SDS03: 12.0mm 

 

SDS04: 15.9mm 

 

SDS06: 25.4mm 

o

 

SDS10: 28.0mm 

 

SDS14: 45.0mm 

 

SDS20: 55mm 

If  the  O.D.  of the ball  is  less  than  95%  or  changes  shape, then the  check  valve  will 
reduce efficiency or stop working. It is then highly recommended to change the ball 
valve immediately. 

 

The ball seat and ball cover should be changed if there are signs of wear or changes 
shape. It is suggested for the ball valve to also be change simultaneously. 

 

 

Summary of Contents for SDS10-SAT-TATS-02

Page 1: ... Air Operated Double Diaphragm Pump 1 SDS10 SAT TATS 02 OPERATION INSTALLATION MAINTENANCE PARTS LIST STOP READ THIS MANUAL CAREFULLY BEFORE INSTALLING OPERATING OR SERVICING THIS EQUIPMENT KEEP OFF THE LOSS UNNECESSARY ...

Page 2: ...ion for the inlet and outlet of the pipes can be tuned When choosing the tube consider the calibre tolerance and pressure resistance This helps to prevent the tube from breaking and leaking Please check and clean the inside of the tube before installation Check for any iron filling trash or any other impurities inside Otherwise it may increase chance of the pump breaking Choose the tube that will ...

Page 3: ...gerous but it is recommended to not hold this state for too long or have an operator beside Otherwise the fluid will leak When stopping the pump follow these instructions close the inlet line for air open the outlet switch and release the pressure remaining inside the pump and pipe If you want to transfer the fluid which can precipitate or easily solidify be sure to transfer the solvent to wash th...

Page 4: ...on number of times The life expectancy of diaphragm is almost ten million operations This is just an estimate The life will cut down when the fluid has dust of metal iron filings wear resisting particles or other foreign matter The O D of ball valve is shown below o SDS03 12 0mm SDS04 15 9mm SDS06 25 4mm o SDS10 28 0mm SDS14 45 0mm SDS20 55mm If the O D of the ball is less than 95 or changes shape...

Page 5: ...DIMENSIONS PART LIST SDS10 SAT TATS 02 ...

Page 6: ......

Page 7: ... PA000112 2 13 Steel Washer PC00058 2 40 Cover of Sequential PB000064 1 14 Pad of Diaphragm PA000224 2 41 Cover Of Sequential PB000065 1 15 Outside Diaphragm PE PB000033N 2 42 O Ring PD000002 2 Outside Diaphragm Teflon PB000028N 2 43 Housing of Sequential PB000020 2 16 Inside Diaphragm PD000085 2 44 Body of Cylinder Base PA000097 1 Diaphragm PD000086 2 45 Hexagon Screw PC000013SW 4 17 Pad of Diaph...

Page 8: ...Address 5 Lyn Parade PRESTONS NSW 2170 E mail sales mtmwarehouse com au Telephone 02 9607 4300 ...

Reviews: