MTI DUCAR DLG4000iSE User Manual Download Page 13

OPERATION 

1

USING EFFICIENCY MODE

The inverter is equipped with an efficiency mode switch 

to minimize fuel consumption. In efficiency mode, the 

inverter will sense the load and adjust the engine RPM 

to the current load requirements. Efficiency mode 

should be used only after the inverter has been warmed 

up to operating temperature.
1. 

To turn on the efficiency mode, press the switch to 

the 

ON

 position).

2. 

If no load is present, the inverter RPM will drop 

down to an idle speed.

3. 

As a load is applied, the inverter will sense the load 

and engine RPM will increase according to the load 

applied.

4. 

To run the inverter at maximum power and RPM, 

press the efficiency mode switch to the 

OFF

 

position.

OVERLOAD RESET

An electrical overload or short circuit will trip the 

overload protection system by disconnecting the 

generator’s AC output even though the engine is still 

running. If this occurs, the overload alarm light will be 

illuminated red and the output indicator light will be off. 

The AC output can be restored as follows:

1. 

Turn off and unplug any electrical devices or 

cords from the 120-Volt AC 

receptacle on the 

control panel.

2.  Press the generator reset button on the control 

panel until the overload alarm light goes off and the 

output indicator light is illuminated green.

3. 

Check that the intended electrical running and 

starting loads do not exceed the generator’s 

capacity or have a licensed electrician rectify any 

fault causing a short circuit in the load.

4. 

Reconnect any electrical devices or cords to the 

receptacles on the control panel and then turn on 

the electrical loads as required.

SWITCHING FUEL SOURCES 

PLEASE REVIEW FUEL SAFETY 

SECTION ON PAGE 

The below assumes that the propane fuel line is already 

attached to the generator securely and safely.

While the unit is running simply turn the 

FUEL 

SELECTOR

 knob to the desired fuel source. If you 

want to switch from gasoline to propane make sure the 

propane tank valve is open before you switch. When 

you move from propane to gasoline shut the propane 

valve after you have switched to gas. 

NOTICE

If you do not plan on operating the unit on propane do not leave 

the propane tank valve open.

When starting on propane the engine may run rough for a few 

seconds while it purges gasoline in the carburetor. 

If the engine fails when switching fuel sources simply restart the 

unit on the fuel source that you switched to. 

STOPPING THE INVERTER

Normal Operation

During normal operation, use the following steps to 

stop your inverter:

1. 

Remove any connected loads from the control 

panel receptacles.

2. 

Allow the inverter to run at “no load” to reduce and 

stabilize engine and alternator temperatures.

3. 

Press and hold the Push Start/

  utton

 

2 3

second

.

see Figure 9).

4. 

.

Figure 9:  Stopping generator

Summary of Contents for DUCAR DLG4000iSE

Page 1: ...USER MANUAL 0RGHO L6 MTI Canada Tél tel 418 839 4127 Français 1 800 463 4398 English 1 800 463 7205 Téléc Fax 1 800 363 7157 www mticanada ca info mticanada ca Distribué par Distributed by ...

Page 2: ... L_LTWSPM H WYVK J ZLY PJL VY THPU LUHUJL PTWYV LTLU L YLZLY L OL YPNO V THRL HU JOHUNL H HU PTL P OV UV PJL VTL PTHNLZ TH HY KLWLUKPUN WVU OPJO TVKLS PZ ZOV U DANGER OPZ THU HS JVU HPUZ PTWVY HU PUZ Y J PVUZ MVY VWLYH PUN OPZ NLULYH VY VY V Y ZHML HUK OL ZHML VM V OLYZ IL Z YL V YLHK OPZ THU HS OVYV NOS ILMVYL VWLYH PUN OL NLULYH VY HPS YL V WYVWLYS MVSSV HSS PUZ Y J PVUZ HUK WYLJH PVUZ JHU JH ZL...

Page 3: ...NGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the generator personal property and or the en...

Page 4: ...e fuel cap with the engine running Never refuel the inverter while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with gasoline Keep sparks open flames or other form of ignition such as match cigarette static electric source away when refueling Never overfill the fuel tank Leave room for fuel to expand Overfilling the fuel tank can...

Page 5: ...match or lighter If a leak is found contact a qualified technician to inspect and repair the LPG system before using the generator DANGER Gasoline and liquid petroleum gas LPG are highly explosive and flammable Explosions and fire can cause severe burns or death Gasoline and gasoline vapor Gas Gasoline is highly flammable and explosive Gas expands and contracts with different temperatures In case ...

Page 6: ... for servicing FEATURES BASIC INVERTER FEATURES 1 5 6 7 8 9 10 11 2 3 4 Roller Board Wheels For easy portability Telescoping Handle Extends and retracts for easy access Carry Handles Built in handles to allow for easy pick up Battery Access Panel Easy access to battery Automatic Choke Unit will automatically set choke for electric and manual start battery must be hooked up even if it is dead for a...

Page 7: ...s to be ingested by the inverter that could Block cooling vents Block air intake system Receptacles These can be used for operating appropriate appliance electrical lighting tools and motor loads Choke lever Control the choke on and off Output Ready LED Indicates the inverter is ready to be used Overload LED Indicates that the inverter is overloaded Low Oil LED Indicates low oil level Fuel Selecto...

Page 8: ...brief start up period WARNING Be sure the inverter is properly connected to earth ground before operating High Altitude Operation Engine power is reduced the higher you operate above sea level Output will be reduced approximately 3 5 for every 1000ft of increased altitude from sea level This is a natural occurrence and cannot be adjusted by engine Increased exhaust emissions can also result due to...

Page 9: ...lectrical appliance INVERTER PARALLELING OPERATION DANGER Never connect the paralleling cord to the inverters with the inverters running The inverters must not be running and both the paralleling cord switches must be off when connecting the cords WARNING Do not attempt to parallel the inverter with any other manufacturers inverters Do not use the paralleling cord for any application other than in...

Page 10: ...inverter is started and the engine gets warm it is not safe to add gasoline to the fuel tank or engine oil to the engine while the engine is running or the en gine and muffler are hot CHECKING AND OR ADDING ENGINE OIL WARNING Internal pressure can build in the engine crankcase while the engine is running Removing the oil fill plug dipstick while the engine is hot can cause extremely hot oil to spr...

Page 11: ...nverter control panel is pointing downward to Propane 4 Remove the plastic cover on the generator propane inlet valve 5 Using your fingers tighten the LPG hose included end below to the generator propane inlet DO NOT OVER TIGHTEN 35 88 Ib in maximum 6 Attach the other end of the hose to a tank of LPG Propane and hand tighten 7 Check all connections for leaks by wetting the fittings with soapy wate...

Page 12: ...osed area Engine exhaust contains carbon monoxide Only operate the inverter outside and away from windows doors and vents 1 Check oil levels see Initial Oil Fill 2 Make sure nothing is plugged into any of the outlets 3 Make sure battery is connected see Hooking Up the Battery 4 Make sure the circuit breakers are properly set see Figure 6 1 2 5 Select fuel source for start up FOR GASOLINE a Make su...

Page 13: ...een 3 Check that the intended electrical running and starting loads do not exceed the generator s capacity or have a licensed electrician rectify any fault causing a short circuit in the load 4 Reconnect any electrical devices or cords to the receptacles on the control panel and then turn on the electrical loads as required SWITCHING FUEL SOURCES PLEASE REVIEW FUEL SAFETY SECTION ON PAGE The below...

Page 14: ...cing Allow hot components to cool to the touch prior to performing any maintenance procedure Internal pressure can build in the engine crankcase while the engine is running Removing the oil fill plug dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin Allow engine oil to cool for several minutes before removing the oil fill plug dip...

Page 15: ...se of used engine oil by dumping the oil into a sewer on the ground or into groundwater or waterways Always be environmentally responsible Follow the guidelines of the governmental agencies for proper disposal of hazardous materials Consult local authorities or reclamation facility ENGINE OIL MAINTENANCE Engine Oil Specification 1 Only use the engine oil specified in Figure 1 2 Only use 4 stroke c...

Page 16: ... reclamation facility 7 Dispose of used soap cleaning solution properly 8 Dry the air filter element by again applying a slow firm squeezing action 9 Return the air filter element to its position in the air cleaner housing 10 Install the air cleaner cover making sure the knobs lock into place 11 Install the engine service panel AIR FILTER MAINTENANCE WARNING Never use gasoline or other flammable s...

Page 17: ...the spark plug from the cylinder head see Figure 17 Figure 1 Remove Spark Plug DRAINING THE FLOAT BOWL 1 Remove the Engine Service Panel to access the carburetor see Figure 11 on page 1 2 Locate the clear plastic hose from the float that is extending towards the bottom of the inverter pull those hose outside the body and place a suitable container under it to catch the drained fuel see Figure 14 F...

Page 18: ...eral minutes if running 2 Move the inverter to a flat level surface 3 Remove the screws holding the muffler cover in place see Figure 1 4 Loosen the clamp holding the spark arrestor onto the muffler Slide the spark arrestor band clamp off the spark arrestor screen 6 Pull the spark arrestor screen off the muffler exhaust pipe 7 Using a wire brush remove any dirt and debris that may have collected o...

Page 19: ... ports are clean of any dirt and debris to ensure the engine does not run hot MAINTENANCE 1 2 3 4 5 BATTERY SERVICE To ensure the battery remains charged the generator should be started every 2 to 3 months and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged overnight Plug the cord from the charger into the charging port on the g...

Page 20: ...n come in contact with an ignition source such as a 1 pilot light of a stove water heater clothes dryer or any other gas appliance or 2 spark from an electric appliance NOTICE Gasoline stored for as little as 60 days can go bad causing gum varnish and corrosive buildup in fuel lines fuel passages and the engine This corrosive buildup restricts the flow of fuel preventing an engine from starting af...

Page 21: ... regulator 1 This can be a normal occurrence caused when liquid propane changes phase to a gas As this process occurs the fuel tank or regulator will cool and allow humid air surrounding the propane tank or regulator to condense into frost 1 As this can be normal providing all the propane fuel handling equipment is functioning normally no remedy is needed 2 The propane tank is not equipped with a ...

Page 22: ... KPYLJ S PU SPUL P O OL KLZPYLK M LS 3 Gasoline not purged from the carburetor before switching to propane YU OL WYVWHUL M LS HUR HS L V JSVZLK 4V L OL M LS ZLSLJ VY HS L V WYVWHUL YU OL NHZVSPUL M LS HS L V VɈ HY OL LUNPUL HUK allow the engine to run until the fuel has been consumed in the carburetor Begin propane start up procedure TROUBLESHOOTING WARRANTY Ducar power products are covered by a o...