                                                                                    2 of 3                                                  Form No. 769-05565

INSPECTION PROCEDURE

 continued

5. Locate the control valve at the operator’s position of the log splitter and look at the control valve end cap (opposite end 

from the control handle). See Figure 2.

6. If the valve has the name “ENERGY” on the end cap, as shown in Figure 3, the valve must be tested. Proceed to the 

“TEST PROCEDURE” 

section on Page 3.

If the end cap on the control valve does not have the name “ENERGY” on it, your log splitter is not affected by this recall

You should stop here.

Control Valve

Control Valve

 21 to 33 Ton

8 Ton

End Cap

End Cap

FIGURE 2

FIGURE 3

If you have any questions related to this Inspection and Test Procedure, call

 

MTD Customer Service toll free at

1-888-848-6038

 

Monday through Friday

 8:00 AM and 5:00 PM Eastern Time

Saturday

10:00 AM to 3:00 PM Eastern Time