background image

User’s Manual

                                                                            SOL20A12LFP-56D2N

 

 
 

 

Electrical specifications  

 

1.0  INPUT 

A.  Solar Panel:  

18V~55VDC 20A max 

B.  AC:  

 

100V~240VAC ,DC Io = 4.7A~5.0A max 

 

Always load first, only balance wattage be used in charge 

 
 

2.0  OUTPUT 

 

Model 

SOL20A12LFP-56D2N 

Output 1 

(upper RJ45) 

56V/1.26A 

(regulated) 

(3/6,4/5+, 1/2,7/8-) 

Output 2 

(rear terminal) 

12V/10A 

(as Bat. Volt.) 

 
 

3.0  Battery Types: 

 

12V LFP26650  LiFePO4 Battery (200Wh ~ 800Wh)

 

 
 

4.0  Protection: 

 

4.1  Battery Polarity Reverse Protection: 

If only battery connected to terminal, when the battery polarities were reversed, 
the model will stop output and REV indicator light on.  
 
When the battery be removed and re-connected to terminal, the function will be 
disable, if there is AC power sources connected, when the battery polarities 
reversed, the battery will be disconnected, the load will be powered from AC 
directly. 
 

4.2  Battery Over Discharge Protection:  

Cuts off the load when the battery voltage is lower than 11V + 0.3V, and auto 
recover when the battery voltage returns to 12 V + 0.3V 

 

4.3  Battery Over Charge Protection:  

Fuse control, over 25A, the fuse will be burnt. 
 

4.4  Solar Panel Polarity Reverse Protection:   

When solar panel polarities be reversed, the charger stop output, it won’t damage 
the charger or end device 

Summary of Contents for SOL20A12LFP-56D2N

Page 1: ...Mstronic Co Ltd SOL20A12LFP 56D2N Solar AC Charge Controller Gigabit PoE Injector USER S MANUAL...

Page 2: ...nd Cisco UPOE 19 rack mountable desktop mountable Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Protection Battery Polar...

Page 3: ...battery and charging 4 LOA Loading indicator the LED lights when the rear panel output terminal is connecting to a device and offering power The LED always on when power ready 5 REV Battery polarity r...

Page 4: ...is connected then no voltage at BAT terminal 3 When a solar panel and AC input are connected to the charger if the voltage of solar panel is higher than 15V then solar panel is always the main power...

Page 5: ...en no load connected 9 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 20A 10 The solar input and battery are not the same grounding must be properly is...

Page 6: ...es were reversed the model will stop output and REV indicator light on When the battery be removed and re connected to terminal the function will be disable if there is AC power sources connected when...

Page 7: ...stop output and auto recover when the terminal back to normal connection 4 7 Battery Output Current Limit The fuse will be burnt when battery output current over 25A 4 8 Load Output Voltage Limit The...

Page 8: ...Data Pair D Vdc BI_DD power Data Pair D Note the model is isolated design the output or input can be shorted to ground FG 7 AC Input to Battery Charger Voltage Float 13 5V 0 1V Equalize 14 2V 0 3V 8...

Reviews: