background image

User’s Manual

                                                                             

SOL10+8-24G2-xxx Series 

 

 

Panel

 

Description

 

 

 

Item  Name 

Descriptions 

POE : 

PoE power input indicator: the LED lights when the PoE input jack (the lower jack) 
has 36V~57V input. 

SOL : 

Solar power input indicator: the LED lights when SOL terminal is connecting to a 
solar panel and the solar panel input voltage is over 24V. 

CHA : 

Charging indicator: the LED lights when  BAT terminal  is connected to battery and 
charging 

LOA : 

Loading indicator: the LED lights when the rear panel output terminal is connecting 
to a device and offering power. 
The LED always on when power ready. 

REV : 

Battery polarity reverse indicator: the LED lights when the battery polarities are 
reversed. (detail description see Sec. 5.1) 

IN : 

PoE Input Jack: the lower RJ45 jack, used for PoE input. Allowed input voltage 
36~57V 

OUT : 

PoE Output Jack: the upper RJ45 jack, used for PoE output; Output voltage 
depends on what model you selected. 

Fuse  Fuse: for output over current protection, limiting the battery output current <= 10A. 

SOL :  Solar Panel Terminal: used to connect the solar panel. 

10 

BAT : 

Battery terminal: used to connect the battery.  
NOTE:  ALWAYS CONNECT THIS TERMINAL FIRST.  
If solar panel or PoE source is installed before the battery, and if the polarities of 
battery are reversed, then the fuse will be burnt.) 

11 

LOA : 

Load Terminal: for wire size up to 10AWG, the output voltage is the same as battery 
voltage.  

12  POE2 

2

nd

 PoE Output Jack:  used for PoE output; Output voltage depends on what model 

you selected, power only, no data. Can be different voltage with front PoE output. 

Summary of Contents for SOL10 plus 8-24G1-24BNN plus 24BNN

Page 1: ...Mstronic Co Ltd SOL10 8 24G2 Series Solar PoE Battery Charger USER S MANUAL...

Page 2: ...rt 802 3at handshake SOL10 8 24G1 56BDN DIN Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fen...

Page 3: ...rsed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57V 7 OUT PoE Output Jack the upper RJ45 jack used for PoE output Output voltage...

Page 4: ...el cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 36V then solar panel is always the...

Page 5: ...10 8 24G2 xxx Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be p...

Page 6: ...regulated SOL10 8 24G1 48ANN 24BNN 24V 10A as Bat Volt 48V 0 625A 12 36 regulated 24V 1 25A 45 78 regulated SOL10 8 24G1 48ANR 24BNN 24V 10A as Bat Volt 48V 0 625A 12 36 regulated 24V 1 25A 45 78 reg...

Page 7: ...al the function will be disable if there is PoE power sources connected when the battery polarities reversed the fuse will be burnt 5 2 Battery Over Discharge Protection Cuts off the load when the bat...

Page 8: ...voltage of the rear terminal is the same as battery 6 GENERAL DESCRIPTION 6 1 Operation Temperature 40 60 Degree 6 2 Storage Temperature 40 85 Degree 6 3 Operation Humidity 5 90 non condensing 6 4 Coo...

Page 9: ...6 Vdc BI_DB power Data Pair B 7 Vdc BI_DD power Data Pair D 8 Vdc BI_DD power Data Pair D Rear RJ 45 Output Power only Depends on individual models Pin Symbol Description 1 Vdc power 2 Vdc power 3 Vd...

Reviews: