USER’S MANUAL 

 
 
 
 

 

 
 

MSTRONIC CO., LTD.

 

 

MSE PSE-SW3G 

3 Port PoE Switch & Extender 

(Repeat Ethernet and PoE)

 

Summary of Contents for MSE PSE-SW3G

Page 1: ...USER S MANUAL MSTRONIC CO LTD MSE PSE SW3G 3 Port PoE Switch Extender Repeat Ethernet and PoE...

Page 2: ...3 series MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring Network Application 3 Model Information 4 Technical Specificatio...

Page 3: ...f and IEEE802 3at standard to receiver and deliver both of Ethernet data and DC power through the traditional UTP or STP cable The PoE Switch can extend Ethernet data and DC power up to 200 meters Thi...

Page 4: ...per port the indicator is unused on PSE SW3G44DN and PSE SW3G42CN Off No power supplied SWITCH LED the right indicator on RJ45 LED STATUS Description P1 P2 UP LINK Link Act Green A network device is d...

Page 5: ...tage as full range voltage 12 to 57VDC P N PSE SW3G11CN 48VDC typical 42 to 57VDC P N PSE SW3G44DN PSE SW3G42CN 48VDC typical switches allow powered by another PoE source 42 57VDC on port UP LINK For...

Page 6: ...n The input voltage must be in the range of 50 to 57VDC if running for 802 3at operation If the PSE SW3G44DN is not powered in above designated input voltage it will only functioning as an Ethernet sw...

Page 7: ...As input voltage non regulated No No 12 57VDC 12 57VDC Higher voltage output REAR or UPLINK No No PSE SW3G42CN 36 57VDC No input 24VDC regulated No No No input 42 57VDC 24VDC regulated No No 36 57VDC...

Page 8: ...t regard to using straight through or crossover cabling Port 1 2 provides Power over Ethernet function that delivers DC power through the data pairs C D pair 4 5 and pair7 8 to the PD Port UP LINK pro...

Page 9: ...nect the other side to your attached device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the LED Indicator section for descriptions of each LED indicat...

Page 10: ...e Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativenVport 7 Negative Vport 8 Negative Vport Be sure the tw...

Page 11: ...wer from PoE midspan and provide power to the PD which follows the IEEE 802 3af at standard in the network The PoE Switch can be installed in a more appropriate position for better performance to exte...

Page 12: ...E SW3G11CN 12 57VDC 12 57VDC 12 57VDC non regulated No No PSE SW3G42CN 36 57VDC 42 57VDC 24VDC regulated No No PSE SW3G44DN 42 57VDC 42 57VDC 42 57VDC non regulated Yes No AC DC Adapter Option MS A150...

Page 13: ...802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T 14880pps for 10base T Address table 1K MAC address table self learning Connect RJ 4...

Page 14: ...ng 2 pair power POWER Green normal Red alarm Power input Port UP LINK from network switch or midspan or option DC power supply Power consumption less than 5W without PD loading Input PSE SW3G11CN PSE...