CROSS SENSITIVITY
1
- SENSOR CARTRIDGE (SC2/MC2) / SENSOR ELEMENT
O
rd
e
ri
n
g N
o
.
A
lc
o
h
o
ls
C
h
lo
ri
n
e
, C
l
2
Eth
an
o
l,
C
2
H
6
O
Eth
yl
e
n
e
, C
2
H
4
C
ar
b
o
n
mo
n
o
xi
d
e
, C
O
C
ar
b
o
n
d
io
xi
d
e
, C
O
2
Su
lp
h
u
r
d
io
xi
d
e
, S
O
2
H
yd
ro
ge
n
sul
p
h
id
e
, H
2
S
N
itr
o
ge
n
d
io
xi
d
e
N
O
2
N
itr
o
ge
n
mo
n
o
xi
d
e
, N
O
H
yd
ro
ge
n
, H
2
MC2-/SC2-
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
E1125-AX
10/0
100/0
100/0 200/0
5000/0
10/<10 10/<20
20/<2
20/0
1000/-10
E1125-BX
10/0
100/0
100/0 200/0
5000/0
10/<12 10/<30
20/0
20/0
1000/-150
E1125-CX
10/0
100/0
100/0 200/0
5000/0
10/<12 10/<30
20/0
20/0
1000/-150
E1125-DX
10/0
100/0
100/0 200/0
5000/0
10/<12 10/<30
20/0
20/0
1000/-150
E1125-EX
10/0
100/0
100/0 200/0
5000/0
10/<12 10/<30
20/0
20/0
1000/-150
E1193-XX
2
300/0
5/0
20/20
35/0
300/0
E1182-AX
E1183-CX
100/0 100 /2
20/38
15/25
5/-12
35/0
100 /2
E1186-DX
20/0
1000/0
100/0
20/31
20/-6
25/0
0
E1189-CX
< 60%
E1198-AX
1000/0 1/1.4
100/0
5000/0
20/-0.2 1/-2
10/8
1000/0
E1185-BX
10-18%
1-3%
E1110-XX
2
2/0
2000/5
5000/0
50/0.5
25/0
50/-1
50/8
100/20
E1190-XX
2
5/45/4 100/0
300/0
5/0
20/10
35/0
300/0
E1187-AX
100/0
100/25 34/8
100/-30
100/0 100/0
E1196-BX
100/0
100/1
10/0
100/-125 100/0 100/1
E1197-XX
2
100/2
100/20
5/1
35/2
100/20
E1188-AX
200/0
5/1
5/8
200/0
E1130-XX
2
1/1
100/0
500/0 400/0
5000/0
30/-0.6 20/-25
50/0
1000/0
E1129-AX
10/15
400/0
5Vol%/0
20/3
20/30
50/5
400/0
E1129-BX
10/15
400/0
5Vol%/0
20/3
20/30
50/5
400/0
E1129-CX
10/15
400/0
5Vol%/0
20/3
20/30
50/5
400/0
E1129-DX
300/0
5/0
15/<5
20/<5
300/0
E1195-XX
2
5Vol%/
Illustration: Gas concentration of cross gas / reaction of sensor
1
The table doesn’t claim to be complete. Other gases, too, can have an influence on the sensitivity. The mentioned cross
sensitivity data are only reference values valid for new sensors.
2
Cross sensitivities valid for all measuring ranges of the sensor.