9.0 STORAGE
Disassemble the valve completely. See section
for detailed instructions on valve disassembly. Remove old grease and debris from
valve pocket with a solvent and inspect for wear or damage per
Drain after testing. All equipment should be drained and lubricated after
testing and prior to storage.
All components and assemblies should be cleaned of dirt, rust, and other
contaminants.
Rust Prevention: Equipment should have exposed metallic surfaces protected
with a rust inhibitor which will not become fluid and run at a temperature less
than 125°F (52°C).
Sealing surface protection: Exposed sealing surfaces should be protected from
mechanical damage.