MSI BEAHM 160-A User Manual Download Page 19

 

                                                                  

 

 

19 | 

P a g e

 

Machine Solutions Inc. 2951 W. Shamrell Blvd. Flagstaff, Arizona 86005 USA 

Tel: 928.556.3109 

• 

Fax: 928.556.3084 

 

[email protected]

 

 www.machinesolutions.com 

 

Figure 9

:

 System Pneumatic Schematic 185-A and 210-A

 

Servicing 

 

Note: Disconnect system main power and air before servicing any part of the product.

 

Heating Element 

 

1. Remove the top cover of the remote heater enclosure. 

 

2. Disconnect the two electrical quick-disconnects. 

 

3. Disconnect the air line from the rear of the heater boot by carefully pulling it rearward.  

 

4. Loosen the rear set screw on the left side of the heater mount block. 
5. Push the heater airline to the side and then carefully slide the heating element rearward until      

it is fully clear of the mount block.                        

 

6. Install the replacement heater with the tab oriented down, inserting it fully into the mount  

 

    block.  

 

7. Re-install the air fitting into the heater boot. 

 

8. Re-connect the electrical connections. 

 

9. Install the top panel. 

 

Summary of Contents for BEAHM 160-A

Page 1: ......

Page 2: ...4 Overview 4 Contents 4 Installation 4 Safety 5 User Alerts 5 Set Up and Configuration 6 System Controls and Features 6 Parameter Settings 9 Temperature 9 Heater Air Flow 9 Pressure 210 A Only 9 Vacu...

Page 3: ...ot Air System Model 160 A 6 Figure 2 Standard Hot Air System Model 185 A 7 Figure 3 Balloon Development System Model 210 A 7 Figure 4 Thermal Nozzles 9 Figure 5 Nozzle Cover 10 Figure 6 System Electri...

Page 4: ...ing tipping heat shrinking welding bonding and balloon forming and tubing expansion The A series Hot Air Stations provide stable precise air temperature control using a high accuracy controller with t...

Page 5: ...prescribed Examples Do not attempt to sit on or climb on the equipment do not place heavy objects or containers of liquid on the machine do not to insert any foreign objects into the machine and do n...

Page 6: ...r The nozzle diameter should be 187 25 larger than the material to be processed 2 Thermal Nozzle Width The width of the thermal nozzle should be sized equal or slightly greater approximately 1 0mm tha...

Page 7: ...heater air flow rate 6 Temperature controller Controls the temperature of the thermal nozzle Table 1 160 A Control and Display functions Figure 2 Standard Hot Air System Model 185 A 185 A and 210 A De...

Page 8: ...e Displays the pressure at the PRESS VAC Port 3 Vacuum Gauge Display vacuum at the PRESS VAC Port 4 Rotary Switch Selects pressure or vacuum at PRESS VAC port 5 PRESS VAC port Access port for the pres...

Page 9: ...emperature will ramp to the new set point Heater Air Flow Rotate the flow meter knob clockwise or counterclockwise until the meter displays the desired value Pressure 210 A Only Rotate the regulator k...

Page 10: ...omponents to be processed within the thermal nozzle for a timed duration 5 Remove the components from the thermal nozzle and position them at the end of the Cooling air nozzle Depress the foot switch...

Page 11: ...is at room temperature Exchanging Thermal Nozzles Note Perform the following steps ONLY when the nozzle is at room temperature Exchanging Thermal Nozzle 1 Loosen the set screw at the top of the nozzle...

Page 12: ...point and the delta is dependent on nozzle style and dimensions as well as method of measurement a Calibrate the temperature controller annually b Calibrate the pressure gauge annually c Verify the fl...

Page 13: ...air flow too low Defective heating element Defective power control Increase air flow Replace heating element Contact Beahm Designs 4 Err code in display Temperature controller software failure Replac...

Page 14: ...14 P a g e Machine Solutions Inc 2951 W Shamrell Blvd Flagstaff Arizona 86005 USA Tel 928 556 3109 Fax 928 556 3084 info machinesolutions com www machinesolutions com System Schematics...

Page 15: ...a g e Machine Solutions Inc 2951 W Shamrell Blvd Flagstaff Arizona 86005 USA Tel 928 556 3109 Fax 928 556 3084 info machinesolutions com www machinesolutions com Figure 6 System Electrical Schematic 1...

Page 16: ...16 P a g e Machine Solutions Inc 2951 W Shamrell Blvd Flagstaff Arizona 86005 USA Tel 928 556 3109 Fax 928 556 3084 info machinesolutions com www machinesolutions com...

Page 17: ...Machine Solutions Inc 2951 W Shamrell Blvd Flagstaff Arizona 86005 USA Tel 928 556 3109 Fax 928 556 3084 info machinesolutions com www machinesolutions com Figure 7 System Electrical Schematic 185 A...

Page 18: ...a g e Machine Solutions Inc 2951 W Shamrell Blvd Flagstaff Arizona 86005 USA Tel 928 556 3109 Fax 928 556 3084 info machinesolutions com www machinesolutions com Figure 8 System Pneumatic Schematic 1...

Page 19: ...enclosure 2 Disconnect the two electrical quick disconnects 3 Disconnect the air line from the rear of the heater boot by carefully pulling it rearward 4 Loosen the rear set screw on the left side of...

Page 20: ...vers without authorization by Beahm Designs Inc mishandling and or mishaps c The product was not sold to customer as new Return Material Authorization Product may not be returned to Beahm Designs Inc...

Reviews: